Mozec PTA is a percutaneous transluminal angioplasty balloon catheter system for treatment of vessels with obstructive disease, sub-total or total occluded peripheral vessel.
Low tip entry profile ensures Crossability through tight lesions
BioGlide™ hydrophilic coating on balloon and shaft provides enhanced Deliverability
Superior force transmission with seamless single tube transition provides FeatherLite™ Pushability
FeatherGlide™ Trackability with low tracking force
Fatigue Resistance balloon material provides better Durability
| Catheter System |
Over-The-Wire (OTW) |
| Balloon Material |
PEBA |
| Catheter Usable Length |
135 ± 2 cm |
| Max Guidewire Compatibility |
0.035″ |
| Min Sheath Comptibility |
5F / 7F (Refer box/IFU for details) |
| Shaft/Balloon Coating |
Biocompatible Hydrophilic Lubricious coating on Balloon + Distal Shaft |
| Distal Puchase |
5.0 ± 1 mm |
| Balloon RO Markers |
2 Platinum-Iridium |
| Nominal Pressure (NP) |
6 / 7 ATM (Refer compliance chart for details) |
| Rated Burst Pressure (RBP) |
12 – 14 ATM (Refer compliance chart for details) |
| DIAMETER / LENGTH |
40 MM |
60 MM |
80 MM |
120 MM |
150 MM |
200 MM |
250 MM |
300 MM |
| 3 mm |
MO35030040B |
MO35030060B |
MO35030080B |
MO35030120B |
MO35030150B |
MO35030200B |
MO35030250B |
MO35030300B |
| 4 mm |
MO35040040B |
MO35040060B |
MO35040080B |
MO35040120B |
MO35040150B |
MO35040200B |
MO35040250B |
MO35040300B |
| 5 mm |
MO35050040B |
MO35050060B |
MO35050080B |
MO35050120B |
MO35050150B |
MO35050200B |
MO35050250B |
MO35050300B |
| 6 mm |
MO35060040B |
MO35060060B |
MO35060080B |
MO35060120B |
MO35060150B |
MO35060200B |
MO35060250B |
MO35060300B |
| 7 mm |
MO35070040B |
MO35070060B |
MO35070080B |
MO35070120B |
MO35070150B |
|
|
|
| 8 mm |
MO35080040B |
MO35080060B |
MO35080080B |
MO35080120B |
MO35080150B |
|
|
|
| 9 mm |
MO35090040B |
MO35090060B |
MO35090080B |
|
|
|
|
|
| 10 mm |
MO35100040B |
MO35100060B |
MO35100080B |
|
|
|
|
|
| 12 mm |
MO35120040B |
|
|
|
|
|
|
|
| 14 mm |
MO35140040B |
Mozec PTA is a percutaneous transluminal angioplasty balloon catheter system for treatment of vessels with obstructive disease, sub-total or total occluded peripheral vessel.
Low tip entry profile ensures Crossability through tight lesions
BioGlide™ hydrophilic coating on balloon and shaft provides enhanced Deliverability
Superior force transmission with seamless single tube transition provides FeatherLite™ Pushability
FeatherGlide™ Trackability with low tracking force
Fatigue Resistance balloon material provides better Durability