{"product_id":"meril-myra-bms-co-cr-peripheral-stent-system","title":"MERIL MYRA BMS CO-CR PERIPHERAL STENT SYSTEM","description":"\u003cp\u003eMyra BMS is the latest generation Co-Cr Stents pre-mounted on OTW balloon catheter system. The newer generation Co-Cr stent platform helps in lowering the strut thickness without compromising on the radial strength and visibility.\u003c\/p\u003e\n\u003cp\u003e• Hybrid stent architecture with Flexi-S connectors : Open Cell + Closed Cell\u003c\/p\u003e\n\u003cp\u003e• Latest generation Cobalt-Chromium (Co-Cr) alloy\u003c\/p\u003e\n\u003cp\u003e• Low strut thickness – 120µ\u003c\/p\u003e\n\u003cp\u003e• Improved Access \u0026amp; Deliverability\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStent Material\u003c\/td\u003e\n\u003ctd\u003eCobalt Chromium L605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrut Thickness\u003c\/td\u003e\n\u003ctd\u003e120µ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStent Diameters (mm)\u003c\/td\u003e\n\u003ctd\u003e5, 6, 7, 8, 9, 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStent Lengths (mm)\u003c\/td\u003e\n\u003ctd\u003e17, 27, 37, 47, 57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean Recoil\u003c\/td\u003e\n\u003ctd\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean Foreshortening\u003c\/td\u003e\n\u003ctd\u003e0.70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery System\u003c\/td\u003e\n\u003ctd\u003eOver-The-Wire (OTW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Catheter Length\u003c\/td\u003e\n\u003ctd\u003e135cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Guidewire Compatibility\u003c\/td\u003e\n\u003ctd\u003e0.035″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiopaque markers\u003c\/td\u003e\n\u003ctd\u003e2 Platinum-Iridum, Swaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Sheath \/ Introducer\u003c\/td\u003e\n\u003ctd\u003e6F – 8F (depending on different stent sizes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Pressure (NP)\u003c\/td\u003e\n\u003ctd\u003e8 – 10 ATM (Refer compliance chart for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Burst Pressure (RBP)\u003c\/td\u003e\n\u003ctd\u003e12 – 14 ATM (Refer compliance chart for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDIAMETER \/ LENGTH\u003c\/th\u003e\n\u003cth\u003e17 MM\u003c\/th\u003e\n\u003cth\u003e27 MM\u003c\/th\u003e\n\u003cth\u003e37 MM\u003c\/th\u003e\n\u003cth\u003e47 MM\u003c\/th\u003e\n\u003cth\u003e57 MM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003ctd\u003eMYB05017B\u003c\/td\u003e\n\u003ctd\u003eMYB05027B\u003c\/td\u003e\n\u003ctd\u003eMYB05037B\u003c\/td\u003e\n\u003ctd\u003eMYB05047B\u003c\/td\u003e\n\u003ctd\u003eMYB05057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003eMYB06017B\u003c\/td\u003e\n\u003ctd\u003eMYB06027B\u003c\/td\u003e\n\u003ctd\u003eMYB06037B\u003c\/td\u003e\n\u003ctd\u003eMYB06047B\u003c\/td\u003e\n\u003ctd\u003eMYB06057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003ctd\u003eMYB07017B\u003c\/td\u003e\n\u003ctd\u003eMYB07027B\u003c\/td\u003e\n\u003ctd\u003eMYB07037B\u003c\/td\u003e\n\u003ctd\u003eMYB07047B\u003c\/td\u003e\n\u003ctd\u003eMYB07057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003ctd\u003eMYB08017B\u003c\/td\u003e\n\u003ctd\u003eMYB08027B\u003c\/td\u003e\n\u003ctd\u003eMYB08037B\u003c\/td\u003e\n\u003ctd\u003eMYB08047B\u003c\/td\u003e\n\u003ctd\u003eMYB08057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003ctd\u003eMYB09017B\u003c\/td\u003e\n\u003ctd\u003eMYB09027B\u003c\/td\u003e\n\u003ctd\u003eMYB09037B\u003c\/td\u003e\n\u003ctd\u003eMYB09047B\u003c\/td\u003e\n\u003ctd\u003eMYB09057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003ctd\u003eMYB10017B\u003c\/td\u003e\n\u003ctd\u003eMYB10027B\u003c\/td\u003e\n\u003ctd\u003eMYB10037B\u003c\/td\u003e\n\u003ctd\u003eMYB10047B\u003c\/td\u003e\n\u003ctd\u003eMYB10057B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003cp\u003eMyra BMS is the latest generation Co-Cr Stents pre-mounted on OTW balloon catheter system. The newer generation Co-Cr stent platform helps in lowering the strut thickness without compromising on the radial strength and visibility.\u003c\/p\u003e\n\u003cp\u003e• Hybrid stent architecture with Flexi-S connectors : Open Cell + Closed Cell\u003c\/p\u003e\n\u003cp\u003e• Latest generation Cobalt-Chromium (Co-Cr) alloy\u003c\/p\u003e\n\u003cp\u003e• Low strut thickness – 120µ\u003c\/p\u003e\n\u003cp\u003e• Improved Access \u0026amp; Deliverability\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377510572079,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/14948_untitled-design-87.png?v=1779383181","url":"https:\/\/i-surgical.com\/products\/meril-myra-bms-co-cr-peripheral-stent-system","provider":"I-Surgical","version":"1.0","type":"link"}