{"product_id":"defi-xpress-defibrillator-monitor-biphasic-with-aed-built-in-printer","title":"Defi® Xpress Defibrillator Monitor | Biphasic With AED \u0026 Built-In Printer","description":"\u003cp\u003eDefi® Xpress Defibrillator Monitor\u003cbr\u003e\nWith voice alarm which can meet your clinical needs from Basic Life Support (BLS)\u003cbr\u003e\nto Advanced Cardiac Life Support (ACLS).\u003c\/p\u003e\n\u003cp\u003eAvailable Color\u003cbr\u003e\nGrey . Blue . White\u003cbr\u003e\nDefibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances\u003cbr\u003e\nDefibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDISPLAY\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eScreen Type: High-resolution display\u003c\/div\u003e\n\u003cdiv\u003eScreen Size: 7 inches (17.7 cm) diagonally\u003c\/div\u003e\n\u003cdiv\u003eSweep Speed: 25mm\/sec\u003c\/div\u003e\n\u003cdiv\u003eInformation: Heart Rate .  Lead\/Pads.  Alarm .  On\/Off  . SpO2 .  AED\u003c\/div\u003e\n\u003cdiv\u003eFunctions and Prompts Alarm Selection and Limits Delivered Energy.\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eDefibrillator\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eWaveform: Biphasic (BTE)\u003c\/div\u003e\n\u003cdiv\u003eCharge Time: Less than 7 seconds with a new fully charged battery.\u003c\/div\u003e\n\u003cdiv\u003eEnergy Display: Monitor display indicates both selected and delivered energy.\u003c\/div\u003e\n\u003cdiv\u003eCharge Prompt Type: Voice and visual prompts.\u003c\/div\u003e\n\u003cdiv\u003eElectrode Impedance Measurement Range: 0-250 ohms.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eECG MONITORING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003ePatient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.\u003c\/div\u003e\n\u003cdiv\u003eLead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.\u003c\/div\u003e\n\u003cdiv\u003eECG Size: 0.25 0.5 1 1.5 2 4 cm\/mV display on monitor.\u003c\/div\u003e\n\u003cdiv\u003eHeart Rate: 20-300BPM.\u003c\/div\u003e\n\u003cdiv\u003eHeart Rate Alarm: On\/Off displayed on monitor user-selectable.\u003c\/div\u003e\n\u003cdiv\u003eSmart Alarms: Beeper\/voice prompts indicate shock able rhythm.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eBATTERY\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003eType: Rechargeable Ni-MH battery 12V.\u003c\/div\u003e\n\u003cdiv\u003eOperating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eSPO2 MODULE (OPTIONS):\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003eMeasurement Range: 30~100% ±2% between 80%~90% others ±5%\u003c\/div\u003e\n\u003cdiv\u003eAlarm Range: User set high limit and low limit.\u003c\/div\u003e\n\u003cdiv\u003eAlarm Accuracy: ±10% within setting values.\u003c\/div\u003e\n\u003cdiv\u003eAlarm time Accuracy: less than 12 sec.\u003c\/div\u003e\n\u003cdiv\u003e1-Meditech Pulse Oximeter\u003c\/div\u003e\n\u003cdiv\u003e2-Nellcor Pulse Oximeter\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eEtCO2 Module (Options):\u003c\/p\u003e\n\u003cdiv\u003eCO2 Range\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e0 to 13%（0－98.8mmHg@BTPS）\u003c\/div\u003e\n\u003cdiv\u003eCO2 Accuracy\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u0026lt;5.0% CO2 (at BTPS) ± 3 mmHg\u003c\/div\u003e\n\u003cdiv\u003e                         \u0026gt;5.0% CO2 (at BTPS) \u0026lt; 10% of reading\u003c\/div\u003e\n\u003cdiv\u003eBreath Rate\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e3～60 BPM\u003c\/div\u003e\n\u003cdiv\u003eMeasurement Accuracy\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e±1BPM\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\n\u003cstrong\u003ePACEMAKER \u003c\/strong\u003e(OPTIONS):\u003c\/h2\u003e\n\u003cdiv\u003eType: VVI\u003c\/div\u003e\n\u003cdiv\u003ePulse Type: rectangular,constant current\u003c\/div\u003e\n\u003cdiv\u003ePulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).\u003c\/div\u003e\n\u003cdiv\u003ePacing Rate: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)\u003c\/div\u003e\n\u003cdiv\u003eMulti-Function Electrode: (MFE) Pads: multipurpose defibrillation\/pacing electrodes\u003c\/div\u003e\n\u003cdiv\u003ePause: Pacing pulse frequency reduced by a factor of 4 when activated\u003c\/div\u003e\n\u003cdiv\u003eRefractory Period: NC(VVI demand do not have this specification)\u003c\/div\u003e\n\u003cdiv\u003ePulse Width: (20+ 1.5 ms)\u003c\/div\u003e\n\u003cdiv\u003eOutput Protection: Fully defibrillator protected and isolated\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eRECORDER\u003c\/strong\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003ePaper: 50mm thermal.\u003c\/div\u003e\n\u003cdiv\u003eSpeed: 12.5mm\/sec 25mm\/sec 50mm\/sec. User-selectable 6-second delay.\u003c\/div\u003e\n\u003cdiv\u003ePrinting Method: High-resolution thermal print head.\u003c\/div\u003e\n\u003cdiv\u003ePrint-out Modes: Manual or automatic user-configurable.\u003c\/div\u003e\n\u003cdiv\u003eOn\/Off Control: Front panel and paddle.\u003c\/div\u003e\n\u003cdiv\u003eAutomatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003e AED MODE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts.\u003c\/div\u003e\n\u003cdiv\u003e Shockable Rhythms: Ventricular fibrillation with amplitude \u0026gt;=200uV ventricular tachycardia with rates \u0026gt;=140bpm and QRS complex wave duration \u0026gt;=140ms.\u003c\/div\u003e\n\u003cdiv\u003e Charge Control: Control on device front panel press key on paddle.\u003c\/div\u003e\n\u003cdiv\u003e Prompts: Voice and visual prompts.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e Manual Mode\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.\u003c\/div\u003e\n\u003cdiv\u003e Synchronized Mode: Synchronizes defibrillator pulse to patient’s\u003c\/div\u003e\n\u003cdiv\u003e R-wave. “SYNC” message displayed on monitor.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSpO2 Module (Options):\u003c\/p\u003e\n\u003cdiv\u003eThe Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section:\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eData Acquisition and Analysis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe Defi® Xpress is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz\u003c\/div\u003e\n\u003cdiv\u003eDiagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic\u003c\/div\u003e\n\u003cdiv\u003eFrequency filter. See chapters 7 on switching between these two options.\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eDefibrillator\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWaveform Details:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eThe tables below provide details of the waveforms delivered by the Defi® Xpress when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output.\u003cbr\u003e\nThe waveforms are characterized by DEFI XPRESS values ​​for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2).\u003cbr\u003e\nThe values ​​shown are within 10%.\u003c\/div\u003e\n\u003cdiv\u003eWaveform: Truncated Exponential Biphasic\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eOutput Energy Accuracy:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e+\/- 10% or 1J (whichever is greater) at 50 ohms\u003c\/div\u003e\n\u003cdiv\u003e+\/- 15% or 1J (whichever is greater) at 25 to 100 ohms\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eEnergy Select:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eExternal: 2 5 7 10 20 30 50 70 100 150 200 300 360 J.\u003c\/div\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCharge Time:\u003c\/strong\u003e\u003cbr\u003e\n\u0026lt; 06 seconds @ 200 J (with a Ni-MH 12 volt – MEDITECH battery ).\u003c\/h3\u003e\n\u003cdiv\u003e\u0026lt; 12 seconds @ 360 J (with a Ni-MH 12 volt – MEDITECH battery after15discharges).\u003c\/div\u003e\n\u003cdiv\u003e\u0026lt; 15 seconds @ 360 J (no battery 90% AC mains voltage)\u003c\/div\u003e\n\u003cdiv\u003eCharge Indicator: Audible and graphic.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e :\u003c\/h3\u003e\n\u003cdiv\u003eAdult paddles pediatric adapter and multipurpose hands-free adapter available.\u003c\/div\u003e\n\u003cdiv\u003eSynchronizer: Delivers energy within 60 msec.\u003c\/div\u003e\n\u003cdiv\u003eDisarm: Front panel switch.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMonitor\/Display\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e3-lead 5-lead patient cable\u003c\/div\u003e\n\u003cdiv\u003eSize: 7 inches (16.5 cm) diagonal non-fade.\u003c\/div\u003e\n\u003cdiv\u003eType: color (TFT)\u003c\/div\u003e\n\u003cdiv\u003eDisplay Resolution: 800 x 600 pixels.\u003c\/div\u003e\n\u003cdiv\u003eSweep Speed: 12.5mm\/s25mm\/s50mm\/s\u003c\/div\u003e\n\u003cdiv\u003eLead Selections: I II III AVR AVL AVF V.\u003c\/div\u003e\n\u003cdiv\u003eFrequency Response: (User-selectable).\u003c\/div\u003e\n\u003cdiv\u003e0.7 to 20 Hz operation mode\u003c\/div\u003e\n\u003cdiv\u003e0.3 to 40 Hz Monitoring mode\u003c\/div\u003e\n\u003cdiv\u003e0.05 to 150 Hz Analysis mode\u003c\/div\u003e\n\u003cdiv\u003e0.5 to 30 Hz AED mode\u003c\/div\u003e\n\u003cdiv\u003eCommon Mode Rejection:\u0026gt;=60dB\u003c\/div\u003e\n\u003cdiv\u003eHeart Rate Meter: 20 to 300 BPM.\u003c\/div\u003e\n\u003cdiv\u003eHeart Rate Alarms: User-selectable.\u003c\/div\u003e\n\u003cdiv\u003eSize: 0.125 0.25 0.5 1 2 4 cm\/mv and auto-ranging.\u003c\/div\u003e\n\u003cdiv\u003eECG Output: 1 V\/mV.\u003c\/div\u003e\n\u003cdiv\u003eHeart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cem\u003eAlarms\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cem\u003eHeart Rate Spo2 Alarm:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eAudible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds.\u003c\/div\u003e\n\u003cdiv\u003eVisual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is.\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eLead Fault Alarm:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eAudible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds.\u003c\/div\u003e\n\u003cdiv\u003eVisual: Lead Fault condition causes a “LEAD FAULT” message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18″ high and is the color of the display text. The dashed line is 5″ Long the width of the display. The signal is not modulated.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysiological Alarms (Spo2):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eAudible: See Heart Rate Alarm\u003c\/div\u003e\n\u003cdiv\u003eVisual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eMute Duration: 90 seconds.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnd-tidal CO2 (EtCO2):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eSafety ETCO2：BF type\u003c\/div\u003e\n\u003cdiv\u003ePower Requirements\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e12.0V±0.2V DC\u003c\/div\u003e\n\u003cdiv\u003ePower Consumption\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e100mA (typical with pump on)  200mA (extreme status)\u003c\/div\u003e\n\u003cdiv\u003eOperating Temperature Range\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e5～50℃\u003c\/div\u003e\n\u003cdiv\u003eShipping\/Storage Temperature Range\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e-20～+70℃\u003c\/div\u003e\n\u003cdiv\u003eRelative Humidity\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e0-85% (non-condensing)\u003c\/div\u003e\n\u003cdiv\u003eDimensions\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e96×91×36mm\u003c\/div\u003e\n\u003cdiv\u003eCO2 Range\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e0 to 13%（0－98.8mmHg@BTPS）\u003c\/div\u003e\n\u003cdiv\u003eCO2 Accuracy\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u0026lt;5.0% CO2 (at BTPS) ± 3 mmHg\u003c\/div\u003e\n\u003cdiv\u003e                         \u0026gt;5.0% CO2 (at BTPS) \u0026lt; 10% of reading\u003c\/div\u003e\n\u003cdiv\u003eBreath Rate\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e3～60 BPM\u003c\/div\u003e\n\u003cdiv\u003eMeasurement Accuracy\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e±1BPM\u003c\/div\u003e\n\u003cdiv\u003eWarm-up Time\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e10 seconds\u003c\/div\u003e\n\u003cdiv\u003eResponse Time\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eDetector: 10mS，\u003c\/div\u003e\n\u003cdiv\u003eSystem: Dependent Upon Implementation, Pneumatics\u003c\/div\u003e\n\u003cdiv\u003eand Water Separation Technique\u003c\/div\u003e\n\u003cdiv\u003eFlow Control\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e50～250ml\/min\u003c\/div\u003e\n\u003cdiv\u003eInterface\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eHighly configurable serial digital interface (TTL\/RS232)\u003c\/div\u003e\n\u003cdiv\u003eAutomatic Offset Calibration\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eTime and temperature based, as well as on-demand\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003cstrong\u003ePacemaker\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eType: VVI\u003c\/div\u003e\n\u003cdiv\u003ePulse Type: rectangular,constant current\u003c\/div\u003e\n\u003cdiv\u003ePulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).\u003c\/div\u003e\n\u003cdiv\u003ePacing Rate: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)\u003c\/div\u003e\n\u003cdiv\u003eMulti-Function Electrode: (MFE) Pads: multipurpose defibrillation\/pacing electrodes\u003c\/div\u003e\n\u003cdiv\u003ePause: Pacing pulse frequency reduced by a factor of 4 when activated\u003c\/div\u003e\n\u003cdiv\u003eRefractory Period: NC(VVI demand do not have this specification)\u003c\/div\u003e\n\u003cdiv\u003ePulse Width: (20+ 1.5 ms)\u003c\/div\u003e\n\u003cdiv\u003eOutput Protection: Fully defibrillator protected and isolated\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eRecorder\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eType: High-resolution thermal array.\u003c\/div\u003e\n\u003cdiv\u003eAnnotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.\u003c\/div\u003e\n\u003cdiv\u003ePaper Width: 50 mm.\u003c\/div\u003e\n\u003cdiv\u003ePaper Speed: 25 mm\/sec 50 mm\/sec 12 Lead 50 mm\/sec\u003c\/div\u003e\n\u003cdiv\u003eDelay: 6 seconds.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eAutomatically set to monitor’s frequency response.\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eHigh Capacity Type: Ni-MH 12V volt – MEDITECH\u003c\/div\u003e\n\u003cdiv\u003eUp to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing\u003c\/div\u003e\n\u003cdiv\u003eProper battery care is required to maintain maximum avail-able capacity.\u003c\/div\u003e\n\u003cdiv\u003eLow Battery Indicator:\u003c\/div\u003e\n\u003cdiv\u003eFlashing low battery icon on display and flashing LED on front panel..\u003c\/div\u003e\n\u003cdiv\u003eRecharge Rate: 80% in 7.5 hours. 100% in 9 hours.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eWeight: 10 pounds (4.95 kg) (basic configuration).\u003c\/div\u003e\n\u003cdiv\u003eSize: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm).\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eOperating:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eTemperature*: 0 to 45° C\u003c\/div\u003e\n\u003cdiv\u003eHumidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe)\u003c\/div\u003e\n\u003cdiv\u003eVibration*: MIL-STD 810E\u003c\/div\u003e\n\u003cdiv\u003eShock \/ Drop*: MIL-STD 810E\u003c\/div\u003e\n\u003cdiv\u003eAltitude: Up to 4572 M (15000 feet)\u003c\/div\u003e\n\u003cdiv\u003eTransport and Storage:\u003c\/div\u003e\n\u003cdiv\u003eTemperature: -30 to 70°C (-20 to 70°C with CO2 probe)\u003c\/div\u003e\n\u003cdiv\u003eHumidity: 15 to 95% RH (non-condensing)\u003c\/div\u003e\n\u003cdiv\u003eAtmospheric pressure: 860 to 1060 hPa\u003c\/div\u003e\n\u003cdiv\u003eShock\/vibration: ISTA 1A\u003c\/div\u003e\n\u003cdiv\u003eEnclosure Protection*:\u003c\/div\u003e\n\u003cdiv\u003eSolid Foreign object: IEC 529 IP2X\u003c\/div\u003e\n\u003cdiv\u003eWater: IEC 529 IPX4.\u003c\/div\u003e\n\u003cdiv\u003eAll tests performed per AAMI DF-2 Defibrillation Standard.\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eOperating Power:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eNi-MH 12 volt – MEDITECH\u003c\/div\u003e\n\u003cdiv\u003eSAED Rhythm Recognition Performance\u003c\/div\u003e\n\u003cdiv\u003eThe DEFI XPRESS SAED algorithm exceeds the requirements of ANSI\/AAMI\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003cstrong\u003eStandard:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eECG Cable (5 Leads) …… 1Pcs\u003cbr\u003e\nAED Pad Adapter  ……….. 1Pcs\u003cbr\u003e\nAED Pad  ……………………..1pcs\u003cbr\u003e\nGround Cable   ……………. 1Pcs\u003cbr\u003e\nPower Cable  ………………. 1Pcs\u003cbr\u003e\nThermal Paper Role …….. 1Pcs\u003cbr\u003e\nCleaning Cloth  ……………. 1Pcs\n\u003ch3\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAED Pad for Child\u003cbr\u003e\nECG Cable (3 Leads)\u003cbr\u003e\nECG Alligator Clips (Metal)\u003cbr\u003e\nSpO2 Cable (Adult hard shell sensor)\u003cbr\u003e\nSpO2 Cable (Adult Soft shell sensor)\u003cbr\u003e\nSpO2 Cable (Neonatal soft sensor)\u003c\/p\u003e\n\u003cdiv\u003eSpO2 Cable (Pediatric hard shell sensor)\u003cbr\u003e\nSpO2 Cable (Pediatric Soft shell sensor)\u003c\/div\u003e\n\u003cdiv\u003eSpO2 Cable (Child finger clip)\u003c\/div\u003e\n\u003cdiv\u003eSpO2 Cable (multi-site Y type)\u003c\/div\u003e\n\u003cdiv\u003eSpO2 External Cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eNIBP Cuff (infant 8 – 14 cm 5\/Bag)\u003c\/p\u003e\n\u003cdiv\u003eNIBP Cuff (Child 13 – 20 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Small Adult 18 – 26 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Adult 26 – 35 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Adult Long 29 – 38 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Large Adult 32 – 42 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Large Adult Long 35 – 44 cm 5\/Bag)\u003c\/div\u003e\n\u003cdiv\u003eNIBP Cuff (Thigh 42 – 50 cm)\u003cbr\u003e\nNIBP Tube 150cm\u003c\/div\u003e\n\u003cdiv\u003ePaper Role\u003cbr\u003e\nDefibrillator Wall mounts (3 Models)\u003cbr\u003e\nDefibrillator Trolley (5 Models)\u003cbr\u003e\nDefibrillator Case\u003cbr\u003e\nEtCO2 Module\n\u003ch4\u003eIrDA USB Adapter for ECG Data transfer\u003c\/h4\u003e\n\u003cp\u003eCD Software  for ECG Data transfer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377534361647,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/15701_defi_C2_AE-xpress-defib.jpg?v=1779383209","url":"https:\/\/i-surgical.com\/products\/defi-xpress-defibrillator-monitor-biphasic-with-aed-built-in-printer","provider":"I-Surgical","version":"1.0","type":"link"}