{"product_id":"blood-coagulation-analyzer-bk-ca02-bk-ca04","title":"Blood Coagulation Analyzer BK-CA02 BK-CA04","description":"\u003ch2 class=\"alcet_title\"\u003eBlood Coagulation Analyzer BK-CA02 BK-CA04\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is suitable for the detection of prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT) and fibrinogen (FIB) in plasma. .\u003c\/p\u003e\n\u003cp\u003eWidely used in blood laboratory, biochemical laboratory, hospital blood laboratory and so on.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e●Dual-channel independent detection, can analyze different items at the same time\u003c\/p\u003e\n\u003cp\u003e●5-inch high-definition touch screen, easy to operate\u003c\/p\u003e\n\u003cp\u003e●Open system, good compatibility, Supports reagents of various specifications\u003c\/p\u003e\n\u003cp\u003e●20,000 results storage\u003c\/p\u003e\n\u003cp\u003e●Equipped with multiple pre-temperature positions to improve detection efficiency\u003c\/p\u003e\n\u003cp\u003e●Built-in thermal printer\u003c\/p\u003e\n\u003cp\u003e●The pipette automatically triggers the measurement, and the measurement time can be accurate to tenths of a second\u003c\/p\u003e\n\u003cp\u003e●Less reagent consumption\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cstrong\u003eechnical Parameter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eModel\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003eBK-CA02\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003eBK-CA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eTest Principle\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eOptical Colorimetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eTest Items\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003ePT, APTT, TT, FIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eTest Channel\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e2 (can test different projects at the same time)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e4 (can test different projects at the same time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eWavelength\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e470nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eDetection Time\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eNormal sample detection time is 20 to 40 seconds, and can be set arbitrarily from 20 to 99 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eSample Incubation Position\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e12\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eReagent Incubation Position\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e5\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eDetection Position Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e37.0±1.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eIncubation Position Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e37.0±1.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eIncubation Time\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e1-999s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eReaction Time\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e1-99s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eReagent Dosage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eMinimum dosage 20μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003e\n\u003ca name=\"_Hlk113530278\"\u003e\u003c\/a\u003eSample Volume\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e20μl~40μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e5-inch high-definition color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eStorage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e20,000 results storage, automatically save measurement data when power off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eRS232 serial interface, support LIS system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003ePrinter\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eBuilt-in thermal printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003eAC100~240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eConsumption\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e70VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e10℃～30℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e≤80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eAtmospheric Pressure\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"556\"\u003e86kPa~106kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eExternal Size (W* D*H)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e360*210*120mm\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e390*250*135mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e3.5kg\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e4.96kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003ePackage Size (W* D*H)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e376*246*316mm\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e445*305*265mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"181\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"252\"\u003e5Kg\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"283\"\u003e7kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eIntroduction:\u003cbr\u003e\nThe blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to the change of the optical density of the test specimen, and the instrument detects the coagulation end point.\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/Blood%20Coagulation%20Analyzer%20BK-CA02.pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003eBlood Coagulation Analyzer BK-CA02.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377517715503,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16313_2587-202209261418187702.jpg?v=1779383191","url":"https:\/\/i-surgical.com\/products\/blood-coagulation-analyzer-bk-ca02-bk-ca04","provider":"I-Surgical","version":"1.0","type":"link"}