{"product_id":"automatic-nucleic-acid-extraction-system","title":"Automatic Nucleic Acid Extraction System","description":"\u003cdiv class=\"alcet_title\"\u003eAutomatic Nucleic Acid Extraction System\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1. Accurate pipetting, air pressure correction can adapt to extreme environments such as flat ground, plateau, island, etc., to ensure the accuracy of pipetting\u003c\/p\u003e\n\u003cp\u003e2. 96 samples can be processed within 60 minutes, realizing high-throughput processing of samples, saving time and effort\u003c\/p\u003e\n\u003cp\u003e3. Reagent position and PCR plate position, can be refrigerated at 4℃\u003c\/p\u003e\n\u003cp\u003e4. With high-efficiency filter, ultraviolet disinfection and sterilization, and safety door functions, effectively prevent microbial pollution\u003c\/p\u003e\n\u003cp\u003e5. Multi-threaded control and three-module extraction can run three different extraction programs at the same time\u003c\/p\u003e\n\u003cp\u003e6. Intelligent temperature control, over-temperature protection function\u003c\/p\u003e\n\u003cp\u003e7. Preset multiple experimental programs, strong compatibility, suitable for various types of sample graphic guides, visualized operations\u003c\/p\u003e\n\u003cp\u003e8. Nucleic acid products can be allocated to the 2*96 PCR reaction system to flexibly construct a variety of different PCR detection systems\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is widely used in various fields such as Entry-Exit Inspection and Quarantine Bureau, Disease Control and Prevention Center, Scientific research institution, Laboratory medicine of all size general hospitals, Blood centers, Independent labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Parameter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eModel\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eBK-AutoHS96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eExtraction Method\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eMagnetic Bead Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eWorking Mode\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eAutomatic sampling + Nucleic acid extraction + PCR reaction system addition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eThroughput\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e1-96, Linear slide type sample rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eExtraction Volume\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e20-1000ul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eProcessing Time\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eComplete the processing of 96 samples within 60 minutes (related to reagents)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eMagnetic Bead Recovery\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e≥98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eTemp Range\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eRT-105℃, Lysis and elution position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eTemp Accuracy\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eHeating Method\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eDry bath heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eHeating Speed\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eRT-100℃≤6min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eShaking Function\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eUp and down oscillation (1-5 gears adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eExtraction Position\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e6 (96-well deep well plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eRobotic arm\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eA robotic arm for adding samples and reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003ePipetting Channel\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e2 Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eLiquid Detection\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003ePneumatic liquid level detection principle, intelligent detection of blocked needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003ePipetting Tip\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e50ul,200ul,1000ul, Disposable black conductive needle with filter element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eTip Amount\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e2-3 Tips\/sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd rowspan=\"3\" valign=\"center\" width=\"143\"\u003ePipetting Accuracy\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e10ul, CV≤3.0%, Accuracy≤5.0%, 50ul Tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"686\"\u003e50ul, CV≤2.0%, Accuracy≤2.0%, 1000ul Tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"686\"\u003e100ul, CV≤1.5%, Accuracy≤2.0%, 1000ul Tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e2-1000ul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd rowspan=\"3\" valign=\"center\" width=\"143\"\u003eWorking Zone\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e2 PCR positions with cooling function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"686\"\u003e6 Tip positions for three types of Tips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"686\"\u003e2 Reagent positions (5ml freezing tube rack position with  cooling function, one reserved position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eProtective function\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eStart up self-test, Power-off protection, High temperature alarm, Over-temperature protection, Tip removal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eDisinfection method\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eUV lamp (30W*1, 8W*1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eIllumination Lamp\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e10W LED lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eYes (Red and blue blinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eSafety Door Design\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eWith safety lock function, the safety door is opened and the program is suspended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e10.1inch touch screen, Windows System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eScanning\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eLAN interface (Bi-direction LIS optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eContamination control\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eBuilt-in air duct and HEPA filter can effectively filter internal aerosols and prevent cross-contamination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eIAP Function\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003eFirmware can be upgraded online at any time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e110\/220V,50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eExternal Size (W*D*H)\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e1420*850*1842mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"143\"\u003ePackage Size (WD*H)\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e1535*970*1180mm (Main instrument)  1540*970*1160mm(Base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"143\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"601\"\u003e360kg(Main instrument) ;190kg(Base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eBK-AutoHS96 Automatic Nucleic Acid Extraction System is a fully automatic high-throughput equipment with automatic sample addition, nucleic acid extraction and PCR system configuration. With magnetic bead extraction reagents, it is suitable for automatic nucleic acid extraction and purification of 1-96 clinical samples of various types. The flexible automatic liquid handling function can accurately complete sample loading and reagent distribution according to requirements. Humanized software design, simple operation, no manual steps, greatly improving work efficiency.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377561264175,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16379_2587-202203191134546483-1.jpg?v=1779383235","url":"https:\/\/i-surgical.com\/products\/automatic-nucleic-acid-extraction-system","provider":"I-Surgical","version":"1.0","type":"link"}