{"product_id":"automatic-chemiluminescence-immunoassay-system-bki1100","title":"Automatic Chemiluminescence Immunoassay System BKI1100","description":"\u003cdiv class=\"alcet_title\"\u003eAutomatic Chemiluminescence Immunoassay System BKI1100\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIn\u003c\/strong\u003e\u003cstrong\u003etroduction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSample Tray：\u003c\/p\u003e\n\u003cp\u003eDisc design, up to 60 samples loading capacity per batch\u003c\/p\u003e\n\u003cp\u003eThe position of sample, standard product and quality control positions can be edited\u003c\/p\u003e\n\u003cp\u003eSupport emergency function.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eReagent Tray：\u003c\/p\u003e\n\u003cp\u003ePatented semiconductor refrigeration technology\u003c\/p\u003e\n\u003cp\u003eUp to 30 reagent position on board with refrigeration at 2-8℃\u003c\/p\u003e\n\u003cp\u003eUp to 30 items can be tested at the same time.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWashing and mixing module:\u003c\/p\u003e\n\u003cp\u003eIncubation, cleaning and testing one-machine design;\u003c\/p\u003e\n\u003cp\u003eFully enclosed independent incubation system with 58 incubation positions；\u003c\/p\u003e\n\u003cp\u003e12 independent cleaning positions;\u003c\/p\u003e\n\u003cp\u003eTriple magnetic separation cleaning technology is adopted;\u003c\/p\u003e\n\u003cp\u003eOriginal photon counting dark chamber.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSample Probe:\u003c\/p\u003e\n\u003cp\u003eExcellent rinsing system make carry-over ≤10-5\u003c\/p\u003e\n\u003cp\u003eLiquid-level and blood coagulation detection system\u003c\/p\u003e\n\u003cp\u003eIntelligent anti-collision function\u003c\/p\u003e\n\u003cp\u003eSampling volume: 15ul-100ul\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRV Loading Module:\u003c\/p\u003e\n\u003cp\u003eReaction vessels can be added by pouring, without manual arrangement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncubation plate:\u003c\/p\u003e\n\u003cp\u003e80 incubation positions\u003c\/p\u003e\n\u003cp\u003eConstant 37°C incubation\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eInstrument Software:Flexible sample test mode: STAT function, automatic dilution, reset function, continuous loading\u003c\/p\u003e\n\u003cp\u003eReagent management: the remaining amount, calibration validity, expiry date management\u003c\/p\u003e\n\u003cp\u003eConsumables management: continuous monitoring and low-level warning\u003c\/p\u003e\n\u003cp\u003eResult management: store search, print and statistics, automatic unit conversion function\u003c\/p\u003e\n\u003cp\u003eLIS\/HIS connection\u003c\/p\u003e\n\u003cp\u003eAuto daily maintenance\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"866\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"252\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eBKI1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eThroughput\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e180T\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eMagnetic particle enzymatic chemiluminescence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eModes of Operation\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eRandom, Batch and STAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eSeparation method\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eMagnetic separation technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eSample Positions\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e60 (Each position could be used as an emergency position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eReagent Positions\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e25 pcs (2-8℃ refrigeration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eIncubation Positions\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eTime to 1st Result\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e18 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e10-200μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eDetection Precision\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eCV≤5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eCarry-over Rate\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e≤10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eCorrelation Coefficient\u003c\/td\u003e\n\u003ctd width=\"613\"\u003er≥0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eCalibration Stability\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e28 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eCalibration Type\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e6\/7-point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd rowspan=\"3\" width=\"252\"\u003eSoftware system\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eWindows 7\/8\/10, 32 or 64 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"613\"\u003eBi-direction, support HL7 protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"613\"\u003eIntuitive User Interface, Intelligent Data Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eInterface\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eTCP\/IP Network interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd rowspan=\"5\" width=\"252\"\u003eOther Function\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eLiquid level detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"613\"\u003eAnti-collision function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"613\"\u003eSample barcode scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"613\"\u003eReagent radio frequency identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"613\"\u003eIntelligent alarm prompt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd width=\"613\"\u003eAC110\/220V，50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003eExternal Size (W*D*H)\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e768*771*568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e94Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"252\"\u003ePackage Size (WD*H)\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e1303*873*854mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"252\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd width=\"613\"\u003e163kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eReagent Menu:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"866\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"235\"\u003eThyroid\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eTSH;TT4;TT3;FT4;FT3;TgAb;TPOAb;TG;Anti-TSHR; CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eAnemia\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eFERRITIN;VB12;FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003eLiver Fibrosis\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eCIV;LN;HA;PIIINP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eHypertension\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eALD;ACTH;Cortisol; Renin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003eFertility\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eβ-HCG;E2;P;T;PRL;FSH; LH;DHEA-S;SHBG;AMH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eGrowth\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003eBone Metabolism\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eBGP; 25-OH-Vit-D; iPTH;BGP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eTumor Marker\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eCA125;CA15-3;CA199;AFP;CEA; t-PSA; f-PSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003ePepsinogen\u003c\/td\u003e\n\u003ctd width=\"630\"\u003ePGI;PGII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eKidney Function\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eβ2-MG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003eRheumatism\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eAnti-CCp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003eDiabetes\u003c\/td\u003e\n\u003ctd width=\"630\"\u003eC-P;INS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"235\"\u003eardiac Marker\u003c\/td\u003e\n\u003ctd width=\"630\"\u003ecTnl; CK-MB;MYO; NT-proBNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"235\"\u003elnflammation\u003c\/td\u003e\n\u003ctd width=\"630\"\u003ePCT;IL-β\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eThe chemiluminescence immunoassay system uses magnetic particle separation technology, which uses magnetic particles as antibody carriers, which can be evenly distributed in the liquid phase reaction system, with faster reaction speed and higher efficiency. Using enzymatic chemiluminescence method, the light signal is more stable. A new generation of enzymatic substrates, with higher sensitivity and faster luminescence.\u003cbr\u003e\nCompared with the international brands, the chemiluminescence immunoassay reagents have good consistency, the coincidence rate can reach more than 95%\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/17-18%20Automatic%20Chemiluminescence%20Immunoassay%20System%20BKI1100.pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003e17-18 Automatic Chemiluminescence Immunoassay System BKI1100.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377520795695,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16320_2587-202309071721289869.jpg?v=1779383194","url":"https:\/\/i-surgical.com\/products\/automatic-chemiluminescence-immunoassay-system-bki1100","provider":"I-Surgical","version":"1.0","type":"link"}