{"product_id":"auto-esr-analyzer-bk-esr20-bk-esr40","title":"Auto ESR Analyzer BK-ESR20 BK-ESR40","description":"\u003cdiv class=\"alcet_title\"\u003eAuto ESR Analyzer BK-ESR20 BK-ESR40\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApplicable to hospital inspection departments, medical laboratories, research institutes, universities, disease control centers, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\" list-paddingleft-2\"\u003e\n\u003cli\u003e7-inch color touch LCD screen, easy to operate, high resolution\u003c\/li\u003e\n\u003cli\u003e80 samples\/hour, rapid detection\u003c\/li\u003e\n\u003cli\u003eRandomly insert sample positions for testing at any time\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal printer for easy data printing\u003c\/li\u003e\n\u003cli\u003eResults are automatically temperature compensated\u003c\/li\u003e\n\u003cli\u003eAdvanced optical testing principles to overcome reading errors in manual methods\u003c\/li\u003e\n\u003cli\u003ePower-off save function, automatically save the test results\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Parameter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable border=\"1\" width=\"800\" cellspacing=\"0\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eModel\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"263\"\u003eBK-ESR20\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"274\"\u003eBK-ESR40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eApplication\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eErythrocyte sedimentation rate analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eInfrared detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"263\"\u003eAnalysis Result\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eWestergren ESR value (mm\/hour)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eThroughput\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"263\"\u003eMaximum 40 tests\/hour\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"274\"\u003eMaximum 80 tests\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eAnalysis Channels\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003e20 (load up to 20 samples for analysis at the same time)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003e40 (load up to 40 samples for analysis at the same time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eLoading Type\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eLoad samples at any time, measure at any time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eAnalysis Time\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e30 minutes or 60 minutes selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eSampling Interval\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0~150mm\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe result is automatically corrected to the result at 18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eResult Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e1mm\/1h and 1mm\/2h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eBlood Level Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e46mm~64mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"263\"\u003eHCT Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.2~1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003ca name=\"OLE_LINK4\"\u003e\u003c\/a\u003e0~\u003ca name=\"OLE_LINK3\"\u003e\u003c\/a\u003e10mm\/h， SD≤1.5mm\/h;\n\u003cp\u003e\u0026gt;10mm\/h, CV≤15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"274\"\u003eChannel Consistency\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0~10mm\/h， SD≤1.5mm\/h;\n\u003cp\u003e\u0026gt;10mm\/h, CV≤15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"263\"\u003eReading Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"262\"\u003eCoincidence\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e≥90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"274\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e7-inch color LCD touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eRS232 serial interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003ePrinter\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eBuilt-in thermal printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eAC100~240,220V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003eExternal Size (W* D*H)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e260*230*190mm\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e360*300*180mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e4.9kg\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e7.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003ePackage Size (W* D*H)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e310*270*340mm\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e395*335*375mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e7.2kg\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"undefined\"\u003e10kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eIntroduction:\u003cbr\u003e\nESR testing has important guiding significance for many clinical diseases, but the traditional standard Westergren method has complicated operation, low work efficiency and large cross-contamination. Automatic ESR analyzer uses advanced infrared light color difference interpretation technology to automatically scan the whole process of red blood cell sedimentation within 30 minutes for the sample of the vacuum blood collection tube, and refer to the Westergren method to measure the standard curve to obtain accurate results.\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/81-82%20Auto%20ESR%20Analyzer%20BK-ESR20%20\u0026amp;%20BK-ESR40.pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003e81-82 Auto ESR Analyzer BK-ESR20 \u0026amp; BK-ESR40.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377524138031,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16329_2587-202209131422150414.jpg?v=1779383198","url":"https:\/\/i-surgical.com\/products\/auto-esr-analyzer-bk-esr20-bk-esr40","provider":"I-Surgical","version":"1.0","type":"link"}