{"product_id":"amplivox-otowave-202-h-tympanometer-w-1000-hz-probe-tone","title":"Amplivox Otowave 202-H Tympanometer w\/ 1000 Hz Probe Tone","description":"\u003cp\u003eThe Amplivox Otowave 202-H provides fast, objective middle ear measurements to assist with the identification of middle ear disorders in neonates, children and adults.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/WhPQLEHh2fg\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures and Benefits\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for handheld and desktop use\u003c\/li\u003e\n\u003cli\u003eDual power functionality\u003c\/li\u003e\n\u003cli\u003e1,000 Hz probe tone\u003c\/li\u003e\n\u003cli\u003eLive display\u003c\/li\u003e\n\u003cli\u003eIpsilateral and contralateral reflex frequencies (0.5, 1, 2 \u0026amp; 4kHz)\u003c\/li\u003e\n\u003cli\u003eEnhanced mode reflex test\u003c\/li\u003e\n\u003cli\u003eAuto pass\/refer evaluation\u003c\/li\u003e\n\u003cli\u003eFully customisable test protocol\u003c\/li\u003e\n\u003cli\u003eUser selectable measurement speeds\u003c\/li\u003e\n\u003cli\u003eInternal memory, connection to optional thermal printer and\/or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaterials Included\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOtowave 202 Tympanometer\u003cimg src=\"https:\/\/www.medicaldevicedepot.com\/v\/vspfiles\/assets\/images\/Otowave_202_Package.jpg\" alt=\"\"\u003e\n\u003c\/li\u003e\n\u003cli\u003e(30) Disposable Ear Tips\u003c\/li\u003e\n\u003cli\u003e(1) Contralateral transducer\u003c\/li\u003e\n\u003cli\u003e(1) Test cavities\u003c\/li\u003e\n\u003cli\u003e(4) AA batteries\u003c\/li\u003e\n\u003cli\u003e(1) Amplivox NOAH impedance module\u003c\/li\u003e\n\u003cli\u003e(1) USB cable\u003c\/li\u003e\n\u003cli\u003e(1) Carrying case\u003c\/li\u003e\n\u003cli\u003e(1) Mains adapter\u003c\/li\u003e\n\u003cli\u003e(1) Portable Printer (Optional)\u003c\/li\u003e\n\u003cli\u003e(2) Paper Roll (Optional)\u003c\/li\u003e\n\u003cli\u003e(1) USB Stick with AmpliSuite 1.2, AmpliSuite NOAH and AmpliSuite\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAvailable Languages:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eEnglish\u003c\/li\u003e\n\u003cli\u003eFrench\u003c\/li\u003e\n\u003cli\u003eGerman\u003c\/li\u003e\n\u003cli\u003eItalian\u003c\/li\u003e\n\u003cli\u003ePortuguese\u003c\/li\u003e\n\u003cli\u003eSpanish\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTympanometry Measurements\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProbe Tone Level and Accuracy: \u003c\/b\u003e79dBSPL +\/-2dB (202-H only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePressure Range and Accuracy: \u003c\/b\u003e+200daPa to -400daPa +\/-10daPa or +\/- 10% (whichever is larger) over range 0.1ml to 5m\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDirection of Sweep:\u003c\/b\u003e Positive to negative\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVolumetric Range and Accuracy: \u003c\/b\u003e226Hz: 0.2ml to 5ml 1000Hz: 0.1ml to 5ml +\/-0.1ml or +\/-5% (whichever is larger)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAnalysis Performed: \u003c\/b\u003eAdmittance peak level in mΩ (1000Hz) \u0026amp; pressure at peak; Gradient in daPa (for 226Hz); Ear Canal Volume (ECV) @ 200daPa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReflex Measurements\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eReflex Type:\u003c\/b\u003e Ipsilateral, contralateral or both\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReflex Frequencies:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIpsilateral and Contralateral:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eUser-selectable from: 500Hz, 1kHz, 2kHz \u0026amp; 4kHz (+\/-2%)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReflex Levels:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIpsilateral:\u003c\/b\u003e 70dBHL to 100dBHL (+\/-3dB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eContralateral:\u003c\/b\u003e 70dBHL to 110dBHL (+\/-3dB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReflex detection threshold: \u003c\/b\u003e0.01ml to 0.5ml +\/-0.01ml (configurable in 0.01ml steps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAnalysis performed: \u003c\/b\u003eReflex maximum amplitude and pass\/fail at each test level\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eData Management\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eInternal Database: \u003c\/b\u003e16 patient records with patient record identifier\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePrinting from connected printer (Optional): \u003c\/b\u003eDesignated high speed portable thermal printer using a wireless, infrared connection (IrDA 9600 baud) is available as an option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePhysical Data\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePower\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMains: \u003c\/b\u003e100-240Vac; 50\/60Hz via Amplivox mains adapter (approved to medical safety standards)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBatteries: \u003c\/b\u003e4 x AA (either Alkaline or NiMH, the latter recharged external to the instrument)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBase Unit\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLength:\u003c\/b\u003e 7.4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWidth:\u003c\/b\u003e 3.3\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHeight: \u003c\/b\u003e1.57\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProbe\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLength: \u003c\/b\u003e5.1\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDiameter: \u003c\/b\u003e0.9\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBase Unit\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e0.66 lbs (Without Batteries, Using Mains Power)\u003c\/li\u003e\n\u003cli\u003e0.95 lbs (With Batteries)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProbe with Connecting Cable:\u003c\/b\u003e 0.24 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStandards\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSafety:\u003c\/b\u003e IEC 60601-1 (including national requirements for US and Canada)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEMC:\u003c\/b\u003e IEC 60601-1-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImpedance:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60645-5 Type 2 tympanometer\u003c\/li\u003e\n\u003cli\u003eANSI S3.39 Type 2 tympanometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCE mark:\u003c\/b\u003e Complies to EU Medical Device directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWarranty Information\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377474428975,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/18030_8507959-6__45355.1709215306.386.513__24414.jpg?v=1779383141","url":"https:\/\/i-surgical.com\/products\/amplivox-otowave-202-h-tympanometer-w-1000-hz-probe-tone","provider":"I-Surgical","version":"1.0","type":"link"}