{"product_id":"amplivox-270-air-bone-and-speech-audiometer-sisi-testing-capable","title":"Amplivox 270 Air, Bone and Speech Audiometer (SISI Testing Capable)","description":"\u003cp\u003eThe 270 diagnostic audiometer is an ideal 2 channel audiometer. With an ergonomic design and a clear layout, the key features of the audiometer can be accessed through dedicated keys.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/AEebzAvYZG4\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\nFeatures and Benefits\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 channel audiometry\u003c\/li\u003e\n\u003cli\u003eFrequency range: 125 - 8000Hz\u003c\/li\u003e\n\u003cli\u003eAttenuation range: -10 - 120dBHL\u003c\/li\u003e\n\u003cli\u003eAir and bone conduction, ULL\/UCL\u003c\/li\u003e\n\u003cli\u003eSpeech testing (live and recorded)\u003c\/li\u003e\n\u003cli\u003eTone selection: Pure, pulsed, warble, continuous\u003c\/li\u003e\n\u003cli\u003eNarrowband masking\u003c\/li\u003e\n\u003cli\u003eSpecial tests: ABLB, Stenger, SISI\u003c\/li\u003e\n\u003cli\u003ePortable and lightweight design\u003c\/li\u003e\n\u003cli\u003eIntegrated talk forward function\u003c\/li\u003e\n\u003cli\u003eThreshold retention function (during test)\u003c\/li\u003e\n\u003cli\u003eThe results can be saved in memory, printed with the optional printer or exported via the included AmpliSuite 1.2 Software compatible interface (AC, BC, speech, and ULL results).\u003c\/li\u003e\n\u003cli\u003eOptional inserts are available; inserts are a small tube with a foam plug and the sound goes through the tube. Inserts will be calibrated to the unit.\u003c\/li\u003e\n\u003cli\u003eAvailable software's to download for free; also included on a USB stick\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12--pro.zip?la=en\u0026amp;rev=A397\"\u003eAmpliSuite 1.2\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eThe ampliSuite 1.2 is the perfect companion for your workflow and can be used without a database. This is the ideal free solution for those using a paper or other database which required PDF session uploads.\u003c\/li\u003e\n\u003cli\u003eThe audiometry module has both tone and speech options which can uploaded directly from the audiometer to the suite.\u003c\/li\u003e\n\u003cli\u003eThe immittance module includes both tympanometry and acoustic reflex options with large graphs which can selected individually for extensive review.\u003c\/li\u003e\n\u003cli\u003eBoth modules includes a wide range of counselling tools, such as adjustable PTA calculation, SRT, customisable normative boxes and pass and refer evaluations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12-noah.zip?la=en\u0026amp;rev=45DE\"\u003eampliSuite NOAH\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eThe ampliSuite NOAH connects seamlessly with NOAH 4 for both modules.\u003c\/li\u003e\n\u003cli\u003eUsing a database enables you to conduct a baseline comparison with as many results as you’d like displayed on one graph in multiple colors for easy comparison.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12--pro.zip?la=en\u0026amp;rev=A397\"\u003eampliSuite PRO\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to be user-friendly with unlimited storage for measurement data and client information, our database has one-click features, automatic backup and advanced login options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaterials Included\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmplivox 270 Audiometer\u003cimg src=\"https:\/\/www.medicaldevicedepot.com\/v\/vspfiles\/assets\/images\/Amplivox_270_Air_Bone_Speech_Sisi_Audiometer.png\" alt=\"\"\u003e\n\u003c\/li\u003e\n\u003cli\u003e(1) Audiometric Headset\u003c\/li\u003e\n\u003cli\u003e(1) Bone Conductor Headset\u003c\/li\u003e\n\u003cli\u003e(1) Patient Response Switch\u003c\/li\u003e\n\u003cli\u003e(1) Mains Adaptor\u003c\/li\u003e\n\u003cli\u003e(1) Integrated Talk Over Function\u003c\/li\u003e\n\u003cli\u003e(50) Audiogram Cards\u003c\/li\u003e\n\u003cli\u003e(1) Carrying Case\u003c\/li\u003e\n\u003cli\u003e(1) USB Stick with AmpliSuite 1.2, AmpliSuite NOAH \u0026amp; AmpliSuite PRO Software \u0026amp; User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\/Input Data\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e Left AC, Right AC, Bone (L\u0026amp;R) insert masking and freefield\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency range (Hz):\u003c\/strong\u003e AC: 125-8kHz BC: 250Hz-8kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency accuracy: \u003c\/strong\u003e\u0026lt;1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistortion:\u003c\/strong\u003e \u0026lt;2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput level range (AC): \u003c\/strong\u003e-10dBHL to 120dBHL (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput level range (BC):\u003c\/strong\u003e -10dBHL to 70dBHL (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput level range (FF):\u003c\/strong\u003e Up to 90dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert masking output:\u003c\/strong\u003e 90dBHL max (250-4kHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput level accuracy:\u003c\/strong\u003e Within 3dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput level step size:\u003c\/strong\u003e 2.5dB\/5dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput transducer options\u003c\/strong\u003e: Standard audiometric headset (AC) and\/or optional insert earphones\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTone present:\u003c\/strong\u003e Pure Tone, Pulsed, Warble or Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMasking:\u003c\/strong\u003e Narrowband\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLock:\u003c\/strong\u003e Synchronous channel lock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClinical tests:\u003c\/strong\u003e SISI, Stenger, ABLB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Integral talk over and talk back facility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorded speech:\u003c\/strong\u003e Tape or CD input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive speech:\u003c\/strong\u003e 2 x microphone input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel indicator: \u003c\/strong\u003eMonitors live and recorded speech\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOAH interface:\u003c\/strong\u003e Transfer of AC, BC speech and ULL test results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Data\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 2 lines of 24 characters (backlit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower: \u003c\/strong\u003e240V ac 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 14\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth: \u003c\/strong\u003e9\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight: \u003c\/strong\u003e3.8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e3.4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety: \u003c\/strong\u003eIEC 60601-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e IEC 60601-1-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudiometric:\u003c\/strong\u003e IEC 60645-1, IEC 60645-2 ANSI S3.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE mark: \u003c\/strong\u003eComplies to EU Medical Device Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWarranty Information\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377483014191,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/18049_8510967-2__25730.1709545712.386.513__69115.jpg?v=1779383148","url":"https:\/\/i-surgical.com\/products\/amplivox-270-air-bone-and-speech-audiometer-sisi-testing-capable","provider":"I-Surgical","version":"1.0","type":"link"}