{"product_id":"amplivox-260-air-bone-and-speech-audiometer","title":"Amplivox 260 Air, Bone and Speech Audiometer","description":"\u003cp\u003eThe 260 Audiometer features everything you need to identify different kind of hearing loss and is regularly used to fit hearing aids all around the world. The device includes air, bone and speech audiometry in a compact and lightweight design.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/j6J4_JT_6Xk\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures and Benefits\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFrequency range: 125 - 8000Hz\u003c\/li\u003e\n\u003cli\u003eAttenuation range: -10 - 120dBHL\u003c\/li\u003e\n\u003cli\u003eAir and bone conduction, ULL\/UCL\u003c\/li\u003e\n\u003cli\u003eSpeech testing (live and recorded)\u003c\/li\u003e\n\u003cli\u003eTone selection: Pure, pulsed, warble, continuous\u003c\/li\u003e\n\u003cli\u003eNarrowband masking\u003c\/li\u003e\n\u003cli\u003eSpecial tests: ABLB, Stenger\u003c\/li\u003e\n\u003cli\u003ePortable and lightweight design\u003c\/li\u003e\n\u003cli\u003eIntegrated talk forward function\u003c\/li\u003e\n\u003cli\u003eThreshold retention function (during Test)\u003c\/li\u003e\n\u003cli\u003eResults can be saved in memory, printed with the optional printer and\/or transferred to a PC with the AmpliSuite 1.2 software\u003c\/li\u003e\n\u003cli\u003eOptional inserts are available; Inserts are a small tube with a foam plug and the sound goes through the tube. Inserts will be calibrated to the unit.\u003c\/li\u003e\n\u003cli\u003eAvailable software's to download for free; also included on a USB stick\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12--pro.zip?la=en\u0026amp;rev=A397\"\u003eAmpliSuite 1.2\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eThe ampliSuite 1.2 is the perfect companion for your workflow and can be used without a database. This is the ideal free solution for those using a paper or other database which required PDF session uploads.\u003c\/li\u003e\n\u003cli\u003eThe audiometry module has both tone and speech options which can uploaded directly from the audiometer to the suite.\u003c\/li\u003e\n\u003cli\u003eThe immittance module includes both tympanometry and acoustic reflex options with large graphs which can selected individually for extensive review.\u003c\/li\u003e\n\u003cli\u003eBoth modules includes a wide range of counselling tools, such as adjustable PTA calculation, SRT, customisable normative boxes and pass and refer evaluations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12-noah.zip?la=en\u0026amp;rev=45DE\"\u003eampliSuite NOAH\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eThe ampliSuite NOAH connects seamlessly with NOAH 4 for both modules.\u003c\/li\u003e\n\u003cli\u003eUsing a database enables you to conduct a baseline comparison with as many results as you’d like displayed on one graph in multiple colors for easy comparison.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/wdh01.azureedge.net\/-\/media\/amplivox\/shared\/zip\/amplisuite-12--pro.zip?la=en\u0026amp;rev=A397\"\u003eampliSuite PRO\u003c\/a\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to be user-friendly with unlimited storage for measurement data and client information, our database has one-click features, automatic backup and advanced login options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaterials Included\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmplivox 260 audiometer\u003cimg src=\"https:\/\/www.medicaldevicedepot.com\/v\/vspfiles\/assets\/images\/Amplivox_260_Air_Bone_Speech_Audiometer.jpg\" alt=\"\"\u003e\n\u003c\/li\u003e\n\u003cli\u003e(1) Audiometric headset\u003c\/li\u003e\n\u003cli\u003e(1) Bone conductor headset\u003c\/li\u003e\n\u003cli\u003e(1) Patient response switch\u003c\/li\u003e\n\u003cli\u003e(50) Audiogram cards\u003c\/li\u003e\n\u003cli\u003e(1) Mains Adapter\u003c\/li\u003e\n\u003cli\u003e(1) Integrated talk over function\u003c\/li\u003e\n\u003cli\u003e(1) Carrying Case\u003c\/li\u003e\n\u003cli\u003e(1) USB Stick with AmpliSuite 1.2, AmpliSuite NOAH \u0026amp; AmpliSuite PRO Software \u0026amp; User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\/Input Data\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs: \u003c\/strong\u003eLeft AC, Right AC, Bone (L\u0026amp;R), insert masking and freefield\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency range (Hz):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC:\u003c\/strong\u003e 125 - 8kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBC:\u003c\/strong\u003e 250Hz - 8kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Accuracy:\u003c\/strong\u003e \u0026lt;1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistortion:\u003c\/strong\u003e \u0026lt;2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level Range (AC): \u003c\/strong\u003e-10dBHL to 120dBHL (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level Range (BC):\u003c\/strong\u003e -10dBHL to 70dBHL (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level Range (FF): \u003c\/strong\u003eUp to 90dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert masking output:\u003c\/strong\u003e 90dBHL max (250-4kHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level Accuracy:\u003c\/strong\u003e Within 3dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level Step Size:\u003c\/strong\u003e 2.5dB or 5dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTone Present:\u003c\/strong\u003e Pure Tone, Pulsed, Warble or Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMasking:\u003c\/strong\u003e Narrowband and broadband\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStenger:\u003c\/strong\u003e Pure tone Stenger test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABLB:\u003c\/strong\u003e Loudness balance test (Fowler)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication: \u003c\/strong\u003eIntegral talk over and talk back facility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorded speech: \u003c\/strong\u003eTape or CD input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Speech: \u003c\/strong\u003e2 x microphone input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel indicator:\u003c\/strong\u003e Monitors live and recorded speech\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOAH Interface:\u003c\/strong\u003e Transfer of AC, BC, Speech and ULL test results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Data\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay: \u003c\/strong\u003e2 lines of 24 characters (backlit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower (battery):\u003c\/strong\u003e 4 x 1.5V “C” type batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower (mains):\u003c\/strong\u003e 100-240V ac 50-60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 10.5\"\u003c\/li\u003e\n\u003cli\u003eWidth: 7\"\u003c\/li\u003e\n\u003cli\u003eHeight: 2.75\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.8 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e IEC 60601-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e IEC 60601-1-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudiometric: \u003c\/strong\u003eIEC 60645-1, IEC 60645-2 ANSI S3.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies to EU Medical Device Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWarranty Information\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377481408559,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/18045_8510968-5__81048.1709545704.386.513__84522.jpg?v=1779383146","url":"https:\/\/i-surgical.com\/products\/amplivox-260-air-bone-and-speech-audiometer","provider":"I-Surgical","version":"1.0","type":"link"}