{"product_id":"50l-80l-160l-270lconstant-temperature-incubatorbjpx-hiv","title":"50L 80L 160L 270LConstant-Temperature Incubator(BJPX-HIV)","description":"\u003ch2 class=\"alcet_title\"\u003e50L 80L 160L 270LConstant-Temperature Incubator(BJPX-HIV)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eConstant-Temperature Incubator(BJPX-HIV)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"constant temperature incubator\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/b80f13a7_2587-202208291520491188.jpg?v=1779382746\" alt=\"constant temperature incubator\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMicrocomputer-based smart temperature controller.\u003c\/p\u003e\n\u003cp\u003eLCD display for settingtemperature and the temperature in the chamber , parameter memory and recoveryfunction for the purpose of protection against power failure , computer system haltand data loss;protection and alarming against excessive temperature , failure ofsensors , creepag and , over-current ; sound \u0026amp; light alarming ; timing function .\u003c\/p\u003e\n\u003cp\u003eSeparate temperature limiting and alarming system，automatic suspension in time of exceeding temperature limit (optional).\u003c\/p\u003e\n\u003cp\u003eUV sterilizing system (optional).\u003c\/p\u003e\n\u003cp\u003eRS-485 portal，capable of being connected with printer or computer , recording variations of temperature parameters (optional) .\u003c\/p\u003e\n\u003cp\u003eDouble door (optional).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"866\" align=\"left\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol span=\"3\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"211\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"157\"\u003eBJPX-H50IV\u003c\/td\u003e\n\u003ctd width=\"157\"\u003eBJPX-H80IV\u003c\/td\u003e\n\u003ctd width=\"170\"\u003eBJPX-H160IV\u003c\/td\u003e\n\u003ctd width=\"170\"\u003eBJPX-H270IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"211\"\u003eCapacity\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e50L\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e80L\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e160L\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e270L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"211\"\u003eTemp.Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRT+5~65℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"211\"\u003eTemp.Resolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"211\"\u003eTemp.Fluctuation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"211\"\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±1℃(37℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"157\"\u003eTime Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1~9999mins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"170\"\u003eShelves(Standard)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"211\"\u003eConsumption\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e250W\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e300w\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e400W\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd rowspan=\"2\" width=\"211\"\u003ePowerSupply\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAC220V±10%,50\/60Hz(Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd colspan=\"4\"\u003eAC110±10%,60Hz(Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"170\"\u003elnternal Size(mm)\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e350*360*410\u003c\/td\u003e\n\u003ctd width=\"211\"\u003e400*400*500\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e500*500*650\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e600*600*750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"170\"\u003eExternal Size(mm)\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e450*520*680\u003c\/td\u003e\n\u003ctd width=\"211\"\u003e500*560*760\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e600*620*910\u003c\/td\u003e\n\u003ctd width=\"157\"\u003e720*690*1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"170\"\u003ePacking Size (mm)\u003c\/td\u003e\n\u003ctd width=\"170\"\u003e550*620*780\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e600*660*860\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e700*720*1010\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e820*790*1120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eGross Weight(kg)\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e40\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e47\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e70\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eFeatures:\u003cbr\u003e\nMicrocomputer-based smart temperature controller.\u003cbr\u003e\nLCD display for settingtemperature and the temperature in the chamber , parameter memory and recoveryfunction for the purpose of protection against power failure , computer system haltand data loss;protection and alarming against excessive temperature , failure ofsensors , creepag and , over-current ; sound \u0026amp; light alarming ; timing function .\u003cbr\u003e\nSeparate temperature limiting and alarming system，automatic suspension in time of exceeding temperature limit (optional).\u003cbr\u003e\nUV sterilizing system (optional).\u003cbr\u003e\nRS-485 portal，capable of being connected with printer or computer , recording variations of temperature parameters (optional) .\u003cbr\u003e\nDouble door (optional).\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/11-12%20Constant-Temperature%20Incubator.pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003e11-12 Constant-Temperature Incubator.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377486290991,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16240_2587-202208291516290309.jpg?v=1779383151","url":"https:\/\/i-surgical.com\/products\/50l-80l-160l-270lconstant-temperature-incubatorbjpx-hiv","provider":"I-Surgical","version":"1.0","type":"link"}