Absorbable sutures are specialized surgical threads designed to dissolve or break down naturally in the body over time. They provide an efficient, reliable solution for wound closure, particularly for internal tissues or cases where removal would be difficult or painful. Made from materials like polyglycolic acid, polylactic acid, or catgut, these sutures offer flexibility in healing support and are commonly used in procedures requiring short-term wound stabilization.

  • Mitsu Polyglactin 910, 5-0, 19mm, 45cm, Reverse Cutting, 3/8 circle, undyed

    MITSU Polyglactin 910 suture leads to growth of fibrous connective tissue due to (minimal) initial inflammatory tissue reaction.

    MITSU gradually loses tensile strength and is finally absorbed by hydrolytic process. During hydrolysis, the copolymer degrades to gylcolic and lactic acids which are then absorbed and metabolized in the body. Significant tensile strength i.e. 75% of the original is retained until initial 14 days, 40%-50% of the original is retained until 21 days (6-0 and larger) & (7-0 and smaller) and 24% of the original is retained until initial 28 days (6-0 and larger).

    There is a subsequent loss between four to five weeks post implantation. Complete absorption of MITSU suture usually takes place between 56 to 75 days.

  • Mitsu Polyglactin 910, 5-0, 12mm, 45cm, Reverse Cutting, 3/8 circle, Violet

    MITSU Polyglactin 910 Suture
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 4-0, 19mm, 45cm, Reverse Cutting, 3/8 circle, Undyed

    MITSU Polyglactin 910 Suture
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 4-0, 12mm, 45cm, Reverse Cutting, 3/8 circle, Violet

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 3-0, 19mm, 70cm, Reverse Cutting, 3/8 circle, undyed

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 3-0, 19mm, Reverse Cutting, 45cm, Undyed Mitsu Polyglactin

    Mitsu Polyglactin 910, 3-0, 19mm, 45cm, Reverse Cutting, undyed

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 2-0, 36mm, 75cm, Round body, 1/2 circle

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Mitsu Polyglactin 910, 2-0 24mm, 70cm, Reverse Cutting, 3/8 circle, Undyed

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Filapron Polyglecaprone 25, 5-0, 16mm, 45cm, Cutting, 3/8 circle, Undyed – PCL50844U Premium

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 4-0, 19mm, 45cm, Reverse Cutting, 3/8 circle, Undyed

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 4-0, 17mm, 70cm, Round Body, 1/2 circle, Violet

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 3-0, 19mm, 45cm, Reverse Cutting, 3/8 circle, Undyed

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Mitsu Polyglactin 910, 4-0, 19mm 70cm, RC, 3/8c, Undyed

    MITSU Polyglactin 910 suture.
    Multifilament, Braided
    75% of the original is retained until initial 14 Days
    40-50% of the original is retained until initial 21 Days
    There is a subsequent loss between four to five weeks post implantation
    Complete absorption of MITSU suture usually takes place between 56 to 75 days

  • Filapron Polyglecaprone 25, 3-0, 25mm, 70cm, Cutting, 3/8c, Undyed

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 3-0, 19mm, 75cm, RC, 3/8c, Violet

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 3-0, 19mm, 70cm, RC, 3/8c, Undyed

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Filapron Polyglecaprone 25, 2-0, 24mm, 70cm, RC, 3/8c

    FILAPRON Poliglecaprone 25 Suture
    Monofilament
    80-60% of original is retained until initial 7 Days DYED
    60-50% of original is retained until initial 7 Days UNDYED
    40-30% of original is retained until initial 14 Days DYED
    30-20% of original is retained until initial 14 Days UNDYED

    There is a subsequent loss between 28 days post implantation
    Complete absorption usually takes place between 90 to 120 days

    FILAPRON suture is composed of poly (glycolide-co-caprolactone)

  • Mitsu Fst Polyglactin 910 , 4-0, 13mm, 75cm, RC, 3/8c, Undyed

    MITSU FST Polyglactin 910 Fast Suture
    Multifilament, Braided
    50% of the original is retained until initial 5 Days
    Approximately 10-14 Days post implantation, the original tensile strength is completely lost
    Complete absorption usually takes place by 42 days