{"title":"PCR Products","description":null,"products":[{"product_id":"pcr-strips-caps","title":"PCR Strips \u0026 Caps","description":"\u003cp\u003ePCR strips and caps allow scientists working with cyclers and enzymes to gain enhanced PCR yield through a\u003cbr\u003e\nfaster transmission of heat from block to the reaction.\u003c\/p\u003e\n\n\n\u003cp\u003ePCR grade products are made from virgin materials, sterile, RNAse, DNAse, human\u003cbr\u003e\nDNA and Pyrogen free.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Optical 0.2ml PCR 8 cap strip","offer_id":45377542881327,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"Nature 0.2ml PCR 8 tube strip","offer_id":45377542914095,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"0.5ml PCR tube","offer_id":45377542946863,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/8645_untitled2-7.png?v=1779383218"},{"product_id":"pcr-microcentrifuge-tubes","title":"PCR Microcentrifuge Tubes","description":"\u003cp\u003ePCR tubes are small tubes made of high-quality virgin polypropylene with a conical bottom and snapcap\u003cbr\u003e\nlead. They have uniform thin walls to facilitate efficient heat transfer to the sample. These tubes are\u003cbr\u003e\nautoclavable and work well with most thermal cyclers.\u003c\/p\u003e\n\n\n\u003cp\u003ePCR grade products are made from virgin materials, sterile, RNAse, DNAse, human\u003cbr\u003e\nDNA and Pyrogen free.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"5.0ml PCR tube","offer_id":45377543864367,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"2.0ml PCR tube","offer_id":45377543897135,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"1.5ml PCR tube","offer_id":45377543929903,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"0.5ml PCR tube","offer_id":45377543962671,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/8655_untitled3-5.png?v=1779383219"},{"product_id":"pcr-centrifuge-tubes","title":"PCR Centrifuge tubes","description":"\n\n\u003cp\u003ePCR grade products are made from virgin materials, sterile, RNAse, DNAse, human\u003cbr\u003e\nDNA and Pyrogen free.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"50ml centrifuge tube, self standing","offer_id":45377544781871,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"50ml centrifuge tube","offer_id":45377544814639,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true},{"title":"15ml centrifuge tube","offer_id":45377544847407,"sku":null,"price":1000.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/8657_untitled8-1.png?v=1779383220"},{"product_id":"pcr-thermal-cycler-tec01","title":"PCR Thermal Cycler TEC01","description":"\u003ch2 class=\"alcet_title\"\u003ePCR Thermal Cycler TEC01\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e*Reliable performance of heating and cooling elements,high-performance temperature control system.\u003cbr\u003e\n*High-performance digital signal processor for precise temperature control.\u003cbr\u003e\n*Excellent temperature uniformity.*Rapid heating and cooling.\u003c\/p\u003e\n\u003cp\u003e*7-inch color touch panel,easy to operate.\u003cbr\u003e\n*Support large-capacity program storage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable border=\"0\" width=\"800\" cellspacing=\"0\" cellpadding=\"0\" align=\"left\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"131\"\u003e\n\u003ccol width=\"102\"\u003e\n\u003ccol width=\"504\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd class=\"et2\" colspan=\"2\" height=\"21\"\u003eMode\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"503\"\u003eTEC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et4\" colspan=\"2\" height=\"16\"\u003eCapacity\u003c\/td\u003e\n\u003ctd class=\"et5\" width=\"503\"\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et4\" colspan=\"2\" height=\"18\"\u003eReaction Volume\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e10~200μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003eTube Type\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"503\"\u003e96×0.2mlPCR plate,8\n\u003cp\u003e×0.2ml PCR tube\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003eBlock Temperature Range\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e4℃~105℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"36\"\u003eHeat Lid Temperature Range\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e30℃~110℃,When the set temperature is lower than 30°,\u003cbr\u003e\nthe Heat Lid will be closed automatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"19\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e±0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"16\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e≤0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"20\"\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"503\"\u003e≤1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et4\" colspan=\"2\" height=\"18\"\u003eBlock Material\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"16\"\u003eGradient Range\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003e30～99℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"19\"\u003eTemperature Differential Range\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003e1～42℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"17\"\u003eProgram\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"undefined\"\u003eA single program can be up to 30 steps,99 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003e7”LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"undefined\"\u003e110V~220V,50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et4\" colspan=\"2\" height=\"18\"\u003eExternal Size(L*W*H)\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003e398*280*257mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"undefined\"\u003e11kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"18\"\u003ePackage Size(L*W*H)\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"undefined\"\u003e495*380*380mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd class=\"et6\" colspan=\"2\" height=\"17\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"undefined\"\u003e17kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eIntroduction:\u003cbr\u003e\nThe thermal cycler is an instrument that performs nucleic acid amplification by polymerase chain reaction.Mainly used inMedical institutions,clinical gene amplification testing laboratories that meet the requirements,scientific research institutes,universities,etc.\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/Brochure-Thermal%20Cycler%20TEC01.pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003eBrochure-Thermal Cycler TEC01.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377557102639,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16152_2587-202401041005074288.jpg?v=1779383229"},{"product_id":"pcr-cabinet-pcr800-pc1000-pcr1200-pcr1300-pcr1500","title":"PCR Cabinet PCR800 PC1000 PCR1200 PCR1300 PCR1500","description":"\u003ch2 class=\"alcet_title\"\u003ePCR Cabinet PCR800 PC1000 PCR1200 PCR1300 PCR1500\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1. LCD display(LED display for PCR1000).\u003c\/p\u003e\n\u003cp\u003e2. UV sterilization system.\u003c\/p\u003e\n\u003cp\u003e3. HEPA filter efficiency 99.999% at 0.3μm.\u003c\/p\u003e\n\u003cp\u003e4. With memory function in case of power-failure.\u003c\/p\u003e\n\u003cp\u003e4. Interlock function: UV lamp only can be switched on when the front window is closed, ensuring operator safety.\u003c\/p\u003e\n\u003cp\u003e5. UV timer (0-90 minutes): When the setting time expires, the UV lamp automatically switches off in preparation\u003c\/p\u003e\n\u003cp\u003efor the next experiment.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PCR Cabinet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/5209ed89_09.png?v=1779382728\" alt=\"PCR Cabinet\" data-original=\"\/\/jlrorwxhqjrilj5q.ldycdn.com\/cloud\/lpBprKkmljSRqimrpnnniq\/09.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels\u003c\/strong\u003e：\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"1000\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"146\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"128\"\u003ePCR-800\u003c\/td\u003e\n\u003ctd width=\"123\"\u003ePCR-1000\u003c\/td\u003e\n\u003ctd width=\"123\"\u003ePCR-1200\u003c\/td\u003e\n\u003ctd width=\"124\"\u003ePCR-1300\u003c\/td\u003e\n\u003ctd width=\"124\"\u003ePCR-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"146\"\u003eExternal Size (W*D*H)\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e800*700\n\u003cp\u003e*1770mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"123\"\u003e1000*705\n\u003cp\u003e*1770mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"123\"\u003e1200*700\n\u003cp\u003e*1770mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"124\"\u003e1300*700\n\u003cp\u003e*1770mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"124\"\u003e1500*700\n\u003cp\u003e*1770mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"146\"\u003eInternal Size (W*D*H)\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e700*595\n\u003cp\u003e*550mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"123\"\u003e900*595\n\u003cp\u003e*560mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"123\"\u003e1100*595\n\u003cp\u003e*550mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"124\"\u003e1200*595\n\u003cp\u003e*550mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"124\"\u003e1400*595\n\u003cp\u003e*550mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"146\"\u003eWork Surface Height\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e750mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd rowspan=\"2\" width=\"146\"\u003eMaterial\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eMain Body: Cold-rolled steel with anti-bacteria powder coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd colspan=\"5\"\u003eWork Table: 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd rowspan=\"2\" width=\"146\"\u003eFront \u0026amp; Side Windows\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5mm toughened glass, anti-UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"123\"\u003eMotorized\u003c\/td\u003e\n\u003ctd width=\"146\"\u003eManual\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMotorized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"146\"\u003eMax Opening\u003c\/td\u003e\n\u003ctd width=\"146\"\u003e300mm\u003c\/td\u003e\n\u003ctd width=\"146\"\u003e320mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e300mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"123\"\u003ePre-Filter\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003ePolyester fiber, Washable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"124\"\u003eHEPA Filter\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e99.995% efficiency at 0.3μm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"146\"\u003eAirflow Velocity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.3-0.5m\/s, speed adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"146\"\u003eNoise\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e≤65dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd rowspan=\"2\" width=\"146\"\u003eUV Lamp\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e20W*1\u003c\/td\u003e\n\u003ctd width=\"123\"\u003e20W*2\u003c\/td\u003e\n\u003ctd width=\"146\"\u003e30W*1\u003c\/td\u003e\n\u003ctd width=\"146\"\u003e30W*1\u003c\/td\u003e\n\u003ctd width=\"146\"\u003e40W*1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd colspan=\"5\"\u003eEmission of 253.7 nanometers, with UV timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"128\"\u003eLED Lamp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8W*2\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e12W*2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"124\"\u003eIllumination\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e≥350lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"146\"\u003eShelf with IV bar\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eStainless steel, 502*150*50mm (W*D*H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"123\"\u003eCaster\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eUniversal caster with leveling feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"124\"\u003eConsumption\u003c\/td\u003e\n\u003ctd width=\"124\"\u003e400W\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e300W\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eWaterproof Socket\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eTwo, total load≤500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAC220V±10%, 50\/60Hz; 110V±10%, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eStandard Accessory\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eUV lamp;\n\u003cp\u003eFluorescent lamp;\u003c\/p\u003e\n\u003cp\u003eBase stand;\u003c\/p\u003e\n\u003cp\u003eWaterproof socket*2;\u003c\/p\u003e\n\u003cp\u003eShelf with IV bar.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e168kg\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e178kg\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e220kg\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e231kg\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e250kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003ePackage Size (W*D*H)\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e960*940\n\u003cp\u003e*1450mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e1150*930\n\u003cp\u003e*1450mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e1350*930\n\u003cp\u003e*1450mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e1450*930\n\u003cp\u003e*1450mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e1650*930\n\u003cp\u003e*1450mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003ePCR operating cabinet is a kind of vertical airflow type equipment which can make the local environment with high cleanliness.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377562345519,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16154_2587-202206061410425435.jpg?v=1779383236"},{"product_id":"fluorescent-quantitative-detection-system","title":"Fluorescent Quantitative Detection System","description":"\u003ch2 class=\"alcet_title\"\u003eFluorescent Quantitative Detection System\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReal- time PCR is used for sensitive, specific detection and quantification of nucleic acid targets. We have developed powerful assay design algorithms, optimized qPCR regent, intuitive data analysis software, and flexible instrumentation to help harness the power of qPCR across a rich and diverse set of applications. Explore our robust solutions for your qPCR-based research.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt can be widely used for Infectious disease research, Food pathogen detection, Waterborne pathogen detection, Pharmaceutical analytics, Stem cell research, Pharmacogenomics research, Oncology and genetic disease research, Plant sciences and agricultural biotechnology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorking principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe temperature step change is controlled by the semiconductor peltier to realize PCR amplification. Use high-sensitivity PD unit to detect fluorescence; Program control channel switching, non-contact excitation\/detection on the top structure, coordinated with motor control x and Y axis movement to achieve 96-hole scanning. Finally, accurate analysis is carried out through powerful software.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Fluorescent Quantitative Detection System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/9282fb0f_2587-202211071134222695.jpg?v=1779382730\" alt=\"Fluorescent Quantitative Detection System\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PCR Laboratory Equipment\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/e3990c78_2587-202211071134278187.jpg?v=1779382731\" alt=\"PCR Laboratory Equipment\"\u003e\u003c\/p\u003e\n\u003cp\u003eThermoelectric cooling module\u003c\/p\u003e\n\u003cp\u003eOptical module\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Fluorescent Quantitative Detection System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/490ea87a_2587-202211071134335122.jpg?v=1779382733\" alt=\"Fluorescent Quantitative Detection System\"\u003e\u003c\/p\u003e\n\u003cp\u003e96-Well Heating Plate\u003c\/p\u003e\n\u003cp\u003eRubber Mat\u003c\/p\u003e\n\u003cp\u003eSemiconductor Peltier\u003c\/p\u003e\n\u003cp\u003eHeat Sink\u003c\/p\u003e\n\u003cp\u003eTop Scanning\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003el Excellent temperature control performance of the instrument, the maximum temperature rise and fall ≥7.0℃\/s.\u003c\/p\u003e\n\u003cp\u003el No edge effect, no optical path correction, top excitation\/detection, non-contact measurement.\u003c\/p\u003e\n\u003cp\u003el Fluorescence detection adopts PD sensor with high sensitivity.\u003c\/p\u003e\n\u003cp\u003el Long-life LED light source, stable emission wavelength, maintenance-free.\u003c\/p\u003e\n\u003cp\u003el 4-channel fluorescence detection, no cross interference between channels.\u003c\/p\u003e\n\u003cp\u003el User-friendly and fully functional software, flexible program setting, comprehensive analysis and reporting functions, all the parameters can be stored.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReal-time PCR hardware\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PCR Laboratory Equipment\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/89694545_2587-202211071134427450.jpg?v=1779382736\" alt=\"PCR Laboratory Equipment\"\u003e\u003c\/p\u003e\n\u003cp\u003eThermoelectric cooling module (TEM) is a semiconductor device composed of many tiny and effective heat pumps. By applying a low-voltage DC power supply, heat will be transferred from one side of the TEM to the other side, resulting in a phenomenon that one side of the TEM becomes hot and the other side becomes cold. Since this phenomenon is completely reversible, when the polarity of the DC power supply is changed, it will be affected. Shift in the opposite direction. This product adopts a long-life series TEM, which provides longer life and more efficiency during thermal cycling.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Fluorescent Quantitative Detection System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/2b8b61e3_2587-202211071136148450.jpg?v=1779382737\" alt=\"Fluorescent Quantitative Detection System\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated design of the scanning module and the heating cover module, relying on its own gravity to compress the heating plate and the reagent cover, and is supported by four compression springs to prevent the sample tube from being crushed; at the same time, the rubber pad around the heating cover is pressed to ensure that there is no external light source interference in the detection ; The bottom of the cam mechanism is used to support the spacing to ensure the smooth sliding of the heating module; the guide rail mechanism on both sides of the heating module prevents the module from shifting and ensures the accuracy of the mechanical scanning structure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PCR Laboratory Equipment\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/35274dbb_2587-202211071136412740.jpg?v=1779382737\" alt=\"PCR Laboratory Equipment\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe software includes functions such as absolute quantification experiment, melting curve experiment, relative quantification (AACT) experiment, and genotyping experiment. Enter the attribute setting interface and select different function modules. Guided flow operation, convenient for users to quickly complete experimental settings. The software can open the recent experiment record template for easy viewing of recent experiments and the creation of new experiments.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Fluorescent Quantitative Detection System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/e853fa63_2587-202211071137004225.jpg?v=1779382739\" alt=\"Fluorescent Quantitative Detection System\"\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolute Quantification Experiment\u003c\/p\u003e\n\u003cp\u003eMelting Curve Experiment\u003c\/p\u003e\n\u003cp\u003eRelative Quantification (AACT) Experiment\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PCR Laboratory Equipment\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/0fde5afc_2587-202211071137169385.jpg?v=1779382740\" alt=\"PCR Laboratory Equipment\"\u003e\u003c\/p\u003e\n\u003cp\u003eGenotyping Experiment\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical parameters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"858\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"257\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFluorescence Quantitative PCR Detection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eLEIA-X4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eSample Capacity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e96x0.1ml PCR plate, 12x8-strip tubes, 96*0.1ml single tube (Transparent Cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eReaction System\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e10~50μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eDynamics Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1-10\u003csup\u003e10 \u003c\/sup\u003ecopies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"186\"\u003eChannel\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"60\"\u003eEmission Light\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"187\"\u003eDetector\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"175\"\u003eDetection Path\u003c\/td\u003e\n\u003ctd width=\"60\"\u003eF1\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eF2\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eF3\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eSuitable Probe\/Dye\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eFAM\/SYBR GREEN\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eVIC\/JOE\/ HEX\/TET\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eROX\/TEXAS-RED\u003c\/td\u003e\n\u003ctd width=\"257\"\u003eCy5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eExcitation Wavelength\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e455~645nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eDetection Wavelength\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e510~710nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eFluorescence Detection Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCV≤2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eFluorescence Detection Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCV≤3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eFluorescence Detection Linearity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003er≥0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"257\"\u003eModule Temp. Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4-105℃(resolution:0.1℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"257\"\u003eRamp Rate\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.0℃\/s(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eTemp. Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.3℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ ±0.3℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eTemp. Control Mode\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eBlock mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eHot-Lid Temp. Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e30-110℃(resolution:0.1℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eScanning Mode\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull plate scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eProgramming\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax 100 Segments for Each Program, Max 99 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eOperation Mode\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eScanning Time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e8.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eSpecial Function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAbsolute quantitative automatic analysis, relative quantification, melting curve analysis, etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eOperation System\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMicrosoft: Windows10 x64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAC 100V~240V,50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003eDimension(L*W*H) Mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e375*505 *375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003ePort Method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eUSB Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"undefined\"\u003ePacking Size(L*W*H) Mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e645*565*605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"undefined\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eReal- time PCR is used for sensitive, specific detection and quantification of nucleic acid targets. We have developed powerful assay design algorithms, optimized qPCR regent, intuitive data analysis software, and flexible instrumentation to help harness the power of qPCR across a rich and diverse set of applications. Explore our robust solutions for your qPCR-based research.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377563689007,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16156_2587-202203191317129506.jpg?v=1779383237"},{"product_id":"novel-coronavirus-2019-ncov-nucleic-acid-detection-kit-fluorescence-pcr","title":"Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)","description":"\u003ch2 class=\"alcet_title\"\u003eNovel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvantage：\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1.Internal control: Human β-Globin gene as the internal control is included into the reagent to verify the validity of the experiment.\u003c\/p\u003e\n\u003cp\u003e2.High sensitivity: The lowest detection limit is 500 copies\/ml.\u003c\/p\u003e\n\u003cp\u003e3.High specificity: Primers and probes are designed for specific fragments of two gene regions, which confirm each other to make the results more accurate. No cross-reactivity with other pathogens with the same site of infection or similar infection characteristics.\u003c\/p\u003e\n\u003cp\u003e4.Strong stability: CV of each channel is all \u0026lt;3%.\u003c\/p\u003e\n\u003cp\u003e5.Multiple Real-time RT-PCR detection: Each channel does not interfere with each other, and the amplification curve is S-shaped.\u003c\/p\u003e\n\u003cp\u003e6.Simple operation: one-step method to complete RT-PCR, The whole procedure can be detected within 80min.\u003c\/p\u003e\n\u003cp\u003e7.Fast speed: The PCR amplification time is less than 80 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/3f5e6d6d_2587-202208301648402786.png?v=1779382742\" alt=\"Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd width=\"294\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e2019-Novel Coronavirus (2019-nCoV) RT-QPCR Detection Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eDetection Principle\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eFluorescence PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eDetection Target\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eNovel coronavirus (2019-Ncov) ORF1ab and N gene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eSample Type\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eHuman oropharyngeal swabs, nasopharyngeal swabs and sputum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eApplicable Instrument\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eFluorescence quantitative PCR instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e-20±5℃, keep away from light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eValid Period\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eUnopened ≥6 months; Opened≥90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e7μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eReaction Volume\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e20μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e500 copies\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eStability\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eCV \u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003eInterpretation of Positive Results\u003c\/td\u003e\n\u003ctd width=\"484\"\u003eCT≤38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003ePacking Specification\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e48T\/box; 60 boxes\/carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd width=\"294\"\u003ePacket Size\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e500*500*500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd width=\"294\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd width=\"484\"\u003e23kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Not Available in the U.s\u003c\/p\u003e\n\n\n\u003cp\u003eThis product selects the ORF1ab and N gene regions of 2019-novel coronavirus, and designs two sets of specific primers and fluorescent probes that cover two sites of the gene at the same time. In order to control the entire extraction and detection process, human β-Globin gene was act as a non-competitive internal control during the extraction and detection process. The RT-PCR reaction solution is pre-mixed, which is convenient, efficient and easy to operate. It utilizes high-efficiency Taq DNA Polymerase and has strong stability. The kit could be used for auxiliary diagnosis and epidemiological surveillance of 2019-novel coronavirus infection.\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/53-54%20Novel%20Coronavirus%20(2019-nCoV)%20Nucleic%20Acid%20Detection%20Kit%20(Fluorescence%20PCR).pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003e53-54 Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR).pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377564901423,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16158_2587-202208301652199639.jpg?v=1779383238"},{"product_id":"monkeypox-virus-mpv-nucleic-acid-detection-kit-pcr-fluorescence-probe-method","title":"Monkeypox Virus (MPV) Nucleic Acid Detection Kit (PCR-Fluorescence Probe Method)","description":"\u003ch2 class=\"alcet_title\"\u003eMonkeypox Virus (MPV) Nucleic Acid Detection Kit (PCR-Fluorescence Probe Method)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is applied to the monitoring and auxiliary diagnosis of monkeypox virus. The application scenarios mainly include hospitals, CDC, scientific research institutions, and third-party medical testing laboratories recognized by health administrative agencies.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\" list-paddingleft-2\"\u003e\n\u003cli\u003eInternal Control: the kit contains Internal Control, which is involved in nucleic acid extraction and PCR detection to avoid false negative results\u003c\/li\u003e\n\u003cli\u003eControl：Both negative and positive control in the kit need to be extracted for environmental monitoring and quality control of PCR detection reagents\u003c\/li\u003e\n\u003cli\u003eHigh Sensitivity: Thedetection limitation is 200 copies\/ml\u003c\/li\u003e\n\u003cli\u003eHigh specificity: No cross reaction with other pathogens\u003c\/li\u003e\n\u003cli\u003eFast Speed: Nucleic acid extraction completed within 10 minutes，and the PCR amplification time is less than 1 hour\u003c\/li\u003e\n\u003cli\u003eCertificate: CE declaration of conformity\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Parameter：\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" align=\"left\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ue-table-interlace-color-single firstRow\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003eMonkeypox Virus (MPV) Nucleic Acid Detection Kit\n\u003cp\u003e(PCR-Fluorescence Probe Method)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eDetection Principle\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003eFluorescence PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eDetection Target\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003eMonkeypox Virus F3L gene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eSample Types\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003eSerum or lesion exudate samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eApplicable Instruments\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003eABI7500、LEIA-X4、FQD-96A, etc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eStorage\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e-20±5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eValid Period\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eReaction volume\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e25ul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eDetection Time\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e＜60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e200 copies\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003ePacking Specification\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e24T\/box or 48T\/box or 96T\/box;\n\u003cp\u003e90 boxes\/carton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-double\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003ePacket Size(L*W*H)\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e500*500*500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ue-table-interlace-color-single\"\u003e\n\u003ctd valign=\"top\" width=\"153\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"400\"\u003e24kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eIntroduction:\u003cbr\u003e\nMonkeypox is a zoonotic disease caused by the monkeypox virus, which can be transmitted from animals to humans as well as from human to human. Monkeypox symptoms often include fever, severe headache, muscle aches, swollen lymph nodes, skin lesions, and more. According to the World Health Organization, more than 50 countries and regions around the world have reported confirmed cases of monkeypox. There is currently no cure for monkeypox, and the World Health Organization urges countries to strengthen surveillance and testing of the infectious disease.\u003cbr\u003e\nThis product is based on real-time fluorescent PCR technology, selects the highly conserved region of the monkeypox virus gene coding region as the target region, designs specific primers and fluorescent probes for PCR amplification, and performs PCR amplification on patient serum and lesion leaching fluid (vesicular fluid, pustule fluid) Qualitative detection of monkeypox virus DNA in It is suitable for auxiliary diagnosis of related diseases caused by monkeypox virus infection.\u003c\/p\u003e\n\u003cdiv class=\"addthis_inline_share_toolbox_vqkn\"\u003e\u003c\/div\u003e\n\u003cp\u003eDownload\u003c\/p\u003e\n\u003cdiv class=\"annex_list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/img.waimaoniu.net\/2587\/Monkeypox%20Virus%20(MPV)%20Nucleic%20Acid%20Detection%20Kit%20(PCR-Fluorescence%20Probe%20Method).pdf\"\u003e\u003ci class=\"iconfont\"\u003e\u003c\/i\u003eMonkeypox Virus (MPV) Nucleic Acid Detection Kit (PCR-Fluorescence Probe Method).pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377565982767,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16160_2587-202207121401577004.jpg?v=1779383239"},{"product_id":"biobase-bk-eo-bk-tc-digital-thermal-cycler-pcr-test-machine","title":"BIOBASE BK-EO BK-TC Digital Thermal Cycler Pcr Test Machine","description":"\u003ch2 class=\"alcet_title\"\u003eBIOBASE BK-EO BK-TC Digital Thermal Cycler Pcr Test Machine\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBK-TC Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e*  Higher precision of temperature control\u003c\/p\u003e\n\u003cp\u003e* Faster heating and cooling speed\u003c\/p\u003e\n\u003cp\u003e* Better block temperature uniformity\u003c\/p\u003e\n\u003cp\u003e* Smaller instrument dimension\u003c\/p\u003e\n\u003cp\u003e* More silent operation environment\u003c\/p\u003e\n\u003cp\u003e* Advanced thermoelectric cooling technology and creative TAS technology\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable border=\"0\" width=\"800\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"237\"\u003eBK-EO\u003c\/td\u003e\n\u003ctd width=\"282\"\u003eBK-TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e96-PCR plate(full-skirted)\n\u003cp\u003e96*0.2ml tubes\u003c\/p\u003e\n\u003cp\u003e12*8-strip\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eCooling Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePeltier-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"282\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eLCD display and touch creen(5.7 inch)\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e6.5 inch, 262 144 color LCD display and touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eTemp. Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.0~99.9℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"237\"\u003e\u003cstrong\u003eHeating Speed Of Ramping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 4℃\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eCooling Speed Of Ramping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 4℃\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eTemp. Uniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e≤±0.3℃\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e≤±0.2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eTemp. Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤±0.1℃(50℃), ≤±0.2℃ (≥90℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eTemp. Control Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBLOCK or TUBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eRamping Range Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1℃~4℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥250 typical programs onboard, unlimited with USB flash drive expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eMax. No. Of Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99. Suitable for nested PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"237\"\u003e\u003cstrong\u003eTime Up\/Down\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0~9 min59s, suitable for long PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eTemp. up\/down\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0~9.9℃,suitable for touchdown PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"237\"\u003e\u003cstrong\u003eAuto Pause\/Power Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eSoak Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"282\"\u003e\u003cstrong\u003eGradient Range Of Temp. Difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1~30℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"237\"\u003e\u003cstrong\u003eGradient Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30~99.9℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"280\"\u003e\u003cstrong\u003eHot-lid Temp. Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRoom temperature +5℃~110℃(default 105℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eHeight Of Hot-lid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAutomatic Adjusted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eAuto Shut-off Function Of Hot Lid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWhile block temperature is lower than set temperature or program ends, the hot-lid will be automatically closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003eUSB\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003eLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100~240V, 50\/60Hz, 600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e335*260*270mm\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e345*260*270mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003ePacking Size(L*W*H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e495*410*395mm\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e495*410*395mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e10.5kg\u003c\/td\u003e\n\u003ctd width=\"undefined\"\u003e12.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"undefined\"\u003e\u003cstrong\u003eCertificates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFerrotec Peltier\/CE\/RoHS2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eBrand BIOBASE\u003c\/p\u003e\n\u003cp\u003eProduct origin CHINA\u003c\/p\u003e\n\u003cp\u003eDelivery time Within 7 days\u003c\/p\u003e\n\u003cp\u003eSupply capacity Factory Direct Supply\u003c\/p\u003e\n\u003cp\u003eBK-EO Features\u003cbr\u003e\n1. Intuitive interfaces\u003cbr\u003e\n2. Superior performance\u003cbr\u003e\n3. Multiple temperature control modes\u003cbr\u003e\n4. Gradient function thermal cycler\u003cbr\u003e\n5. Smart block\u003cbr\u003e\n6. Three modes of operation for your choice\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377569849391,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16162_2587-202111091531418745.jpg?v=1779383243"},{"product_id":"biobase-bk-aⅰ-bk-aⅱ-pcr-machine-thermal-cycler-pcr","title":"BIOBASE BK-AⅠ BK-AⅡ Pcr Machine Thermal Cycler Pcr","description":"\u003ch2 class=\"alcet_title\"\u003eBIOBASE BK-AⅠ BK-AⅡ Pcr Machine Thermal Cycler Pcr\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"800\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBK-AI\u003c\/td\u003e\n\u003ctd\u003eBK-AII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Thermal Cycler\u003c\/td\u003e\n\u003ctd\u003eGradient Thermal Cylcer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardModule\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e96 Module: 96 wells*0.2ml or 9677Module: 96 wells*0.2ml+77 wells*0.5ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eOptional Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e48Module:48wells* 0.2ml+48wells*0.5ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e384 Module: 384 wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMulti-purpose Module: 9677 Module+In-situ Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating And Cooling Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNewest generation Peltier-based technology, with long life up to 1,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7°Color Touch Screen, graphical display of protocols and running status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Flash Drive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUnlimited storage of protocols with USB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunications Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2USB 2.0 and LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlock Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0℃~100℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Heating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5℃\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Cooling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4℃\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Uniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤ ±0.2℃（at 95℃）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤ ±0.2℃（35℃-100℃）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMode Of Temperature Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSim-tube \u0026amp; Block mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamping Rate Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGradient\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGradient Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.3℃（35℃~100℃）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn Uniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.3℃ (at 95℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGradient Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003ctd\u003e35℃~99.9℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. Differential Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003ctd\u003e1℃~30℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGradient Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003ctd\u003e12 Column\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eHeat LID\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight of Heated lid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSteplessly Adjustable lid, accommodatesall kinds of PCR tubes, strips and plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInnovative TOP-OPEN technology realizesopen and lift the lid in one step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeated Lid Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30℃~99.9℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Number of Programs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax.10,000 programs onboard, unlimited storage of protocols with USB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.Step \u0026amp;Max.Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 steps,100 typicalcycles, max60,000nestingcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime \u0026amp; Temp. Increment\/Decrement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes, available for long PCR \u0026amp; Touchdown PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Pause\/Auto Restart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-userlogin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePassword-based authentication prevents from view, copy and alteration ofprotocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTm Calculator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAutomatically calculates the melting and annealing temperaturethrough inputtwo primer sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold At 4℃\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes, an infinite incubation time at low temperature forovernight working\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramwizard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes, create PCR protocols with only a few clicks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Report\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes, provideobjective andpreciseinformation forwhole running process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePC remote control to manage more than 100 units of A100\/A200 across the network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eOther Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGlobal switch power supply:85V~265V,50-60Hz Max.600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO 9001:2000 ,CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Size(L*W*H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e430mm*344mm*345mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9.8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eFeatures:\u003cbr\u003e\n1. 7” colorfull touch screen, graphicallydisplay.\u003cbr\u003e\n2. Effortlessly interchangeable modules, swapped in seconds without tools.\u003cbr\u003e\n3. 10,000 protocols storable on board.\u003cbr\u003e\n4. Durable premium peltier element, ensure long life and high quality.\u003cbr\u003e\n5. Large storage of 10,000 programs on board, enhancing friendly operation.\u003cbr\u003e\n6. Update software through USB flash drive.\u003cbr\u003e\n7. Outstanding uniformity, producing best PCR result.\u003cbr\u003e\n8. Global universal switch power(85V-265V), increasing safety \u0026amp; reliability.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377570537519,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16164_2587-202110251728598847.jpg?v=1779383244"},{"product_id":"biobase-bk-96a-fluorescence-quantitive-pcr-detaction-system-thermal-cycler","title":"BIOBASE BK-96A Fluorescence Quantitive Pcr Detaction System Thermal Cycler","description":"\u003ch2 class=\"alcet_title\"\u003eBIOBASE BK-96A Fluorescence Quantitive Pcr Detaction System Thermal Cycler\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"nei-table\"\u003e\n\u003ctable width=\"800\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eFluorescence Quantitative PCR Detection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eFQD-96A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e96x0.2ml PCR plate, 12x8-strip tubes, 96*0.2ml single tube(Transparent Bottom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReaction system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e5~100μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamics Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e1-1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedical instrument registration certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eG.X.Z. 20153400273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmission Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e500-800nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF1\u003c\/td\u003e\n\u003ctd\u003eF2\u003c\/td\u003e\n\u003ctd\u003eF3\u003c\/td\u003e\n\u003ctd\u003eF4\u003c\/td\u003e\n\u003ctd\u003eF5\u003c\/td\u003e\n\u003ctd\u003eF6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable probe.dye\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFAM,SYBR GREEN I\u003c\/td\u003e\n\u003ctd\u003eHEX\/VIC\/TET\/JOE\/CY3\/NED\/TAMRA\u003c\/td\u003e\n\u003ctd\u003eROX,TEXAS-RED\u003c\/td\u003e\n\u003ctd\u003eCy5\u003c\/td\u003e\n\u003ctd\u003eCy5.5\u003c\/td\u003e\n\u003ctd\u003eReserved path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e300~800nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e500~800nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule temp. range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e4-105℃(resolution:0.1℃) withSOAK Low Temp.storage Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRampRate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e4.0℃\/s(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. Control accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e±0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. uniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e≤ ±0.3℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. control mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eBlock mode andTube Mode\n\u003cp\u003e(Automaticcontrolbasedonliquid level)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eContinuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGradient Temp. Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e1-36℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHot-lid Temp. Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e30-110℃(Adjustable, Defaultby105℃ and Automatic Hot-lid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluorescenceintenseDetection Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScanning Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eFull plate scanning and designated line scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eMax 20 Segments for Each Program, Max 99 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScanning time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e5.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eAbsolute quantitative automatic analysis, relative quantification, SNP Analysis, melting curveanalysis,6 independent temperature zones, HRMmulti-channel crosstalk calibration, background correction, auto gain, customized parameters,etc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eMicrosoft:Windows7\/Windows8.1\/ Windows10 Software:excel2000\/2002\/2003\/2007\/2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin computer configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eRAM:512M,hardware space:10GB CPU:Pentium 4 virtual memory≥1000MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e100-240V 50\/60Hz 600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension(L*W*H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e410*386*352mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eSupportUSBandRS232data port andBluetoothport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eFerrotec Peltier\/CE\/EMC\/RoHS2.0\/PICC\n\u003cp\u003eProduct quality liability insurance\/IVD\/MET\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e720*680*640mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e55kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eFeatures：\u003cbr\u003e\n1. Whole block scanning and formulated line scanning mode, 96-well double-colour scaning takes only 5.5s\u003cbr\u003e\n2. 6 channels fluorescencedetection,no cross talk between different channels.\u003cbr\u003e\n3. Unique bottom detection,compatible to reaction volume down to 5μl\u003cbr\u003e\n4. New automatic hot lid,automatic open and close which is prevenT reagent evaporation\u003cbr\u003e\n5. LED excitation light source with super long service life\u003cbr\u003e\n6. New TE module with special technique to ensure long service life\u003cbr\u003e\n7. Available for a variety of scientific research and clinical applications.\u003c\/p\u003e\n","brand":"I-Surgical","offers":[{"title":"Default Title","offer_id":45377571455023,"sku":null,"price":0.0,"currency_code":"NAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/9964\/8559\/files\/16166_2587-202110161503368599.jpg?v=1779383245"}],"url":"https:\/\/i-surgical.com\/collections\/pcr-products-1.oembed","provider":"I-Surgical","version":"1.0","type":"link"}